KB729 DT400 Series Throttles - Function Controls

The DT400 can control Functions 1 - 12.Note: DT400 can access F0-F12 when used with the DCS50 Zephyr or DCS100 Super Chief command station. DT400 can only access F0-F8 when used with a DB150 Super Empire Builder command station.To enter Fn (function) mode:1. Determine which throttle you want to control functions on and make it the active throttle by single clicking the throttle knob or by turning the throttle knob a couple of clicks.2. DT400’s numeric keypad is always active in function mode during normal loco operations. When the mode indicator on your DT400 shows Fn, simply press any number ...

KB840 Zephyr - Functions F0-F8

DCS50 Zephyr can control Functions F0 - F8. Most DCC mobile decoders have function outputs that you can use to control lamps, LEDs, sound, smoke generators and other on/off devices installed in your locomotives. Most locomotives made today come with a head light and sometimes with a rear light, too. With DCC, these are controlled by the decoder’s function outputs. You can also install additional DCC controlled lighting such as cab lights, Mars lights, ditch lights, rotating beacons and others on your locos. The addition of these functions can add to the fun and realism of your locomotives.You must have ...

KB4 Zephyr Quick Start Guide

DCS50 Zephyr - Quick Start Guide 1. Unpacking Your ZephyrUnpack your box and locate the DCS50 Command Station and the PS315 power supply. 2. Before You BeginBefore proceeding to the next step, make sure the Throttle Knob is turned all the way to “STOP” and the Direction/ Brake lever is set to “BRAKE”. 3. Connecting the Pieces TogetherOn the back of the DCS50, locate the gray screw terminal strip. On this strip, locate the two terminals labeled “RAIL A” and “RAIL B”. Attach your layout track wires to these terminals. It does not matter which is which. 4. Turn on ...

KB60 BDL168 - Connecting two RX4's

The BDL168 manual states that 2 RX4's can be connected but it only shows how to connect one of them on Aux 2. How is the second RX4 connected? The RX4 is a 4 Zone Transponding Receiver Add-on for BDL16 series occupancy detectors. Each RX4 is made up of 4 RX1 sensors, a ribbon cable and a connector that lets you plug the unit into a BDL16-series detector. The earlier BDL16 and BDL162 occupancy detectors had the capacity for hosting one RX4. BDL16 & BDL162 boards are labeled with AUX1 & AUX2. Only the AUX2 connection should be used for ...

KB27 DT402 - Controlling Functions

The DT402 Throttle will control up to 29 functions in walkaround and radio modes. When operating in IR Mode the DT402 series throttles will control up to 9 functions (F0-F8). The numeric keypad is always active in the normal Fn operation mode. The functions that are currently on for the active loco will be displayed on the top line of the DT402 display. The following figure shows an example of how the display looks when functions 0 and 1 are turned on for loco 1652 on the R Throttle. Controlling Functions F0-F12 1. Determine which throttle you want to control ...

KB217 Zephyr - Quick Start Guide

Setting up your new Zephyr: Unpack the DCS-50 command station and the PS-315 power supply. On the back of the DCS-50,locate the gray screw terminal strip.On this strip, locate the two terminals labeled “RAIL A “and “RAIL B”.Attach these terminals to your track wires.It does not matter which is which. Before proceeding to the next step,make sure the throttle knob [1] is turned all the way to “stop” and the direction/brake lever [2] is set to”brake”. [See photo blelow]. Now, find the plug on the back of the DCS-50 marked “POWER IN, 15 VAC, 2.5 AMPS”. This is where you ...

KB58 BDL168 - Connecting to a "Direct Home" Wired Layout

Direct Home Layout Wiring Digitrax strongly recommends direct home wiring where each power district and its booster are electrically isolated. This method of wiring has safety advantages and makes troubleshooting problems easier. In addition, direct home wiring makes detection work more prototypically. With direct home wiring, the BDL168 can determine and indicate whether any of its 4 zones is powered or not (possibly short-circuited) even when there is nothing on the rails in the detection sections. The BDL168 factory-set logic causes the detection sections to show "occupied" if the associated zone's power is off (because in this case, detection is ...

KB286 LocoNet Cable Connectors

Previously, we have recommended RJ12 connectors for LocoNet cables. While there have been online sources such as Digi-Key, Mouser and others, they have become harder to find locally. There now appears to be a easily available alternative. Many national big-box home improvement stores have RJ11 6P6C meaning they are 6 position 6 conductor and can be used as RJ12 although labeled as RJ11. These must not be confused with four conductor connectors since LocoNet has six conductors. You will need the connectors, the six-wire flat cable and a crimping tool. We paid $20.00 in February, 2008, for such a tool ...

KB179 Zephyr - Q&A, DCS50 as a Booster

If a Zephyr has been switched to run as a booster/throttle (no command function), can it still be used to program locomotives on the programming track? No, when using the DCS50 as a booster, the programming outputs are disabled. Programming is a function of the command station only, so when the Zephyr is toggled to booster mode, it loses the programming function. If a Zephyr has been switched to run as a booster, does the throttle still work? Yes, but you must assign an unique throttle ID to the Zephyr which is acting as a booster. Assigning Throttle Identities To ...

KB401 Life-Like N-Scale GP18 Modifications needed for the DN163K2 decoder

The Life-Like GP18 locomotive can be modified to accept the DN163K2 board replacement decoder. The locomotive samples used by Digitrax for this instatllation needed to have the frame engagement clearance slots under the cab on the fireman-side widened about 1mm towards the rear of the locomotive (long hood end). This can be done with a small file or Dremel type tool, to allow the decoder to properly engage the casting with the power tab on this side. The engineer-side slots are OK to fit the decoder power pickup tab on this side. Be sure to check the motor tabs are safely ...

KB806 DS64 - Stationary Address Programming

If you have more than four turnouts, you will need to program the addresses.The DS64 has 4 Output pairs labeled 1R & 1G, 2R & 2G, 3R & 3G, and 4R & 4G.  The DS64 is shipped from the factory with these outputs programmed as Switch Addresses 01, 02, 03, and 04 respectively. You can set the Switch Address of each of these four Outputs to any value from 01 - 2048.NOTE:  During this procedure the DS64 must be connected to an active LocoNet with an active command station.1. On the DS64’s control panel, press and hold the ID button ...

KB590 Q&A - Powering DS64

  Q:  How do you connect more than one DS64 to a single power supply like a PS14 to power them or do you need a separate power supply for each DS64? A:  One power supply can be used if it can provide adequate power for all the DS64s it is powering. The PS14 has a built-in circuit breaker; when it exceeds its capacity, it will shut down, cool off and then start up again. If you are experiencing this behavior then you need to add one or more PS14s to provide enought power for the DS64s you have connected. Our recommendation of one ...

KB667 DT300 - L Throttle and R Throttle Knobs

The DT300 Throttle has two throttle knobs, allowing you to select and control two locomotives.  We refer to the throttle knob on the left side as the L THROTTLE and the throttle knob on the right side as the R THROTTLE. This corresponds to the L and R labels that appear on the DT300 near the throttle knobs.The throttle knobs on the DT300 use “encoders” to control speed and direction of the locomotive. The encoder can be pressed or rotated to “activate” the throttle. Pressing the throttle knob once activates that encoder. Pressing the knob twice will change the direction ...

KB57 BDL168 - Connecting to a "Common Rail" Wired Layout

Common Rail Wiring Many older model railroads use Common Rail wiring because they were initially wired to operate with electrical toggle switches. Conversion to DCC is possible with Common Rail, but it is not recommended. Whole layout common rail is a method of wiring layouts where power districts and their boosters are electrically connected using a common rail or common power bus return wire. Whole layout common rail wiring is a disadvantage when it comes to detection systems since detectors cannot independently monitor whether zone power is on or off so they can't tell whether occupancy detection is working in ...

KB120 Decoder Installation in the H0-scale Con-Cor Pioneer Zephyr

Application Note: Con-Cor HO-Scale Zephyr steps needed for the DZ125PS decoder installation Step 1: Carefully remove the body from the frame. There are four clips along each side of the body. (See red arrows) We have found if you start at the rear of the body with a small flathead screwdriver and carefully pry the body outward to remove the back clip, you can move the screwdriver forward to release the others. Once the body is completely removed, carefully lift the light board from its holders on the bulkheads. (See blue arrows) Be very careful as the pins that hold ...

KB639 PR1- FX Lighting Effects Setup

When you click on the "FX-Setup" button a second menu screen appears which contains the special light effects for the FX decoder. If the decoder you are programming is not capable of FX effects, this section will not apply to your situation.On this screen we have access to F0 Forward Light, F0 Reverse Light, F1, F2, F3 & F4. The programming directions and choices are the same for each function. The pull down field to the right of this shows you which effect is assigned to that particular function. The following is a list of choices: No effect, normal function ...

KB945 What does the NMRA Conformance Seal mean?

It means just what it says. "This Product Conforms To All Applicable NMRA Standards." An NMRA Conformance Seal is NOT an endorsement by the NMRA. It is NOT a guarantee by the NMRA or by the manufacturer. It is merely a statement that a particular product conforms to a particular test set up and administered by NMRA volunteers to assess whether, in their opinion, the product conforms to a particular NMRA Standard. Interpretations of this statement vary widely depending on whom you ask for clarification.The Real Issue is InteroperabilityInteroperability means that you don’t have to worry about a single source ...

KB73 TSMK - Terminal Strip Mounting Kit

The TSMK, Terminal Strip Mounting Kit, includes 2 terminal strip boards with resistors for easy installation. The Digitrax Terminal Strip Mounting Kit makes it simple to connect any scale or model signal to the Digitrax signaling system without soldering. Simply connect the wires from the signal to the TSMK’s screw terminals and plug it in to the SE8C’s Signal Driver Cable. Using the Terminal Strip circuit boards You can attach any of a variety of types of model signal masts in any scale you choose to the Terminal Strip Mounting Kit. The Terminal Strip Mounting Kit has 10 screw terminals ...

KB314 RoHS / Lead Free Production Q&A

Q: What is RoHS? A: The RoHS Directive stands for "the restriction of the use of certain hazardous substances in electrical and electronic equipment". This Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants. Q: When did the directive become effective in the EU? A: July 1, 2006 Q: How does this affect products shipped to countries outside the EU? A: The United States and Canada have not yet instituted RoHS as of January ...

KB205 Case Study: Texas & Southwestern Part 6 of 11 - Wiring the Railroad

This section discusses the installation of the physical wiring of the Texas & Southwestern. Underneath the completed Texas & Southwestern are various wires and cables which allow you to operate your railroad. Initially, seeing all these wires can be intimidating, but as you will note, they have been grouped and bundled so that identifying the individual wires is easy. There are two groups of wires under the railroad; one group, the power bus, delivers power to the tracks and to the stationary decoders that operate the track switches. The other group of wires is the black cable for LocoNet and ...

KB1046 Powering the DCS240

The PS615 is the Digitrax recommended power supply for the DCS240 in 5 amp mode.  For operations at 8 amps the PS2012 is the recommended power supply. When using the PS2012 special wiring considerations need to be used when powering both the DCS240 and legacy boosters from the same PS2012.  Leagacy boosters are defined as the DCS100, DCS200, DB150, DB200 or DB100.  Please see the separate article “Powering your DCS240 with a PS2012” and the additional notes below. The DCS240 may be powered either using the barrel plug connector or the screw terminals labeled “+” and “- “. The barrel ...

KB987 General Command System Troubleshooting and Tools

This article stops in a strange place??  We need to find the rest of it and split it up into meaningful chunks.  Also needs meta stuff Troubleshooting in General:Regardless of the guides, manuals, tips, suggestions, experts or whatever, troubleshooting can occasionally degenerate into a vast chasm of darkness and confusion.  It would be impossible to cover all the areas that have, can or may cause problems. This is a general guide to identifying and resolving problems with Digitrax Complete Train Control.  Keep Good Records:Although it may seem to be a pain while setting up your Digitrax system, keeping layout records ...

KB1063 IPLing and Track Power with the DT602/D

IPLING From time to time the latest DT602 family throttle firmware will be updated and will be posted on the product support page.  These updates may slightly modify the DT602's operation, based on customer feedback/requests and priority support issues discovered. If you are happy with the operation of your DT602, and have no issues or new features you may want, it is not required to perform an available update. All DT602 family throttles should only be firmware updated or IPL'd while plugged directly into a working LocoNet. The Digitrax provided DMF file for field updating DT602's can be used for IPL of any ...

KB1048 Digitrax Command Control - The Future Is Now (2016 version)

Digitrax Complete Train Control By Zana & A.J. Ireland Digitrax Complete Train Control makes reliable, realistic train operation and simplified layout wiring a reality. Digital Command Control is incorporated within the Digitrax system to let you control multiple trains independently on the same section of track without blocking. In the real world, engineers control the speed and direction of real trains. Engines operate under their own power independent of the track. Each engine has its own motion characteristics like how fast it speeds up (acceleration) and how long it takes to slow down (deceleration). A locomotive's performance is influenced by ...

KB1062 SDH164K1 Function Connections

Series 4 decoders like the SDH164k1's will conform to the 10-pin wiring diagram   Function pads for F1 and F2 are located on the SDH164K1 boards on opposite sides by the front headlight. Functions 3 and 4 are located on the 10-pin wire harness, with the Brown wire being the F3 negative and the Yellow wire being the F4 negative.  F3 and F4 functions have a common positive connection to the solder point labeled in the middle of the board.     The common LED sizes used are 3 mm and 5 mm.