The DT402R is our basic Simplex Radio Throttle. The DT402R gives you direct control of two locos at a time with all the powerful features and flexibility serious model railroaders demand. The DT402R super throttle is designed to handle nearly every aspect of layout control. You can run trains and consist, control up to 30 functions such as sound, program decoders, set up and operate routes, and much more. Simply plugin to select, then you're ready to go.
Updating and Using DT402R R2 and DT402 IR R2 throttles with your DCS240. Access to expanded slots in the DCS240 are only available to Tethered DT402 throttles with IR and Radio(RF1) throttle options set to off and DT402D throttles. By default these options are set to OFF in the DT402 R2. DT402R throttles can access expanded slots in the DCS240 if IR and Radio(RF1) throttle options are set to off. The DT402R will still operate in simplex radio mode with the DCS240 however it will only have access to standard slots. Practically, this means that you have two options for ...
Selecting a locomotive-Safety Selection While unplugged, the DT402 (IR only) and DT402R (IR and Simplex Radio) operate as one-way transmitters. The DT402 and DT402R must be plugged into LocoNet to select an available locomotive address. After an address is selected, you can unplug from LocoNet and run the selected addresses with infrared or simplex radio. The throttle will automatically convert to infrared or simplex radio operation for all speed, direction, function, operations mode programming, and switch commands. The DT402D throttle has full duplex radio capabilities. Once the 402D has been configured to communicate with a UR92, the full functionality of ...
Notes on IPL updating DT402 Throttles to R2 DT402 throttles can be updated to R2 using any compatible PC connection, including the DCS240 and PR3. Always make sure you are using the latest version of DigiIPL to update your hardware. When updating DT402D throttles the RF24 module must also be updated to the latest RF24 firmware. After updating the DT402s to R2 it is recommended that you reset the throttle to factory default. If you encounter any issue updating your DT402 throttle, the IPL update process can be repeated to resolve any issues. Occasionally running the update twice or 3 ...
DT402 R2 Release Notes Access to Expanded Slots Updating the DT402 to R2 gives the throttle access to expanded slots in the DCS240 Advanced Command Station. Access to these expanded slots are only available when IR and Radio(RF1) options are set to OFF in your throttle. This means that throttles working in IR mode or Simplex Radio will not have access to the expanded slots. Simplex Radio throttles(DT402R) will have access expanded slots if radio(RF1) is set to off and the throttle is plugged in. It is recommended that throttles be factory reset after upgrading the firmware to R2. By ...
This is a feature that helps prevent having the same address selected on multiple throttles and creating unexpected operations. When you steal you are truly stealing control of the locomotive instead of sharing it. When using a DT402 R2 throttle with an Advanced Command Station featuring expanded slots, each throttle ID is associated with the Loco Addresses it has selected. With a when you select a Loco that is selected on another throttle the second throttle will take ownership of the Loco and it will be deselected from the first throttle. By first throttle will display “StealZap” meaning it has ...
The DCS240 offers 400 locomotive slots and can support up to 400 throttles. These slots can be broken down in to standard slots and expanded slots. There are 120 standard slots in the DCS240, these slots are accessible using any Digitrax throttle. There are an additional 280 expanded slots available to DT402 R2 (tethered and Duplex) and later throttles. The DCS240 identifies the throttle type being used and assigns and adjusts the slots accordingly. Expanded capability throttles are given the Expanded slots first, leaving the standard slots available for legacy throttles. All this is done in the background and will ...
The ability of a variety Digitrax throttles to work together on layout equipped with a variety of wireless technologies is part of the beauty of LocoNet. With LocoNet, it is simple to add components to the system and have all of them work together. Digitrax infrared throttles will operate on any layout equipped with UR90 infrared receivers, UR91 simplex receivers and/or UR92 duplex transceivers. All of these panels are equipped with infrared receivers. All current model Digitrax throttles have infrared emitters that will work wirelessly with any panel that has an infrared receiver. All current Digitrax throttles can also be used ...
Q: If you buy the infra ready set and down the road want to upgrade to the radio is it necessary to buy a whole new set? If not what is required to upgrade the existing set? A: The DT400 or DT402 can be converted to DT402D duplex radio or DT402R simplex radio. The conversion must be done by Digitrax. If you plan on using the IR features of the DT400 or DT402 , you will need one or more UR90 infrared receivers.If you convert the DT400 or DT402 to duplex radio, you will need a UR92 duplex transceiver which handles both infrared ...
What is the difference between Simplex and Duplex wireless operations and what are the advantages of each?The Digitrax DT400R, DT402R and UT4R throttles operate at the 916.5Mhz radio frequency. These throttles both use the UR91 for radio communication. The DT402D and UT4D operate at 2.4Ghz. They require the UR92 for radio communication. The move to Duplex is meant to improve radio operations and add radio range. Simplex (UR91) and Duplex (UR92) can operate on the same layout without any issues or interference with each otherWith duplex radio: You’ll select and run your locomotives without plugging in. You'll dispatch locomotives ...
1. Plug the DT402 series throttle into any functioning Digitrax LocoNet System or other LocoNet compatible system and you are ready to get started! You can use any LocoNet jack on your system. 2. After you plug the DT402 into your LocoNet, you will briefly see the DT402 splash screen: This screen shows the throttle type: DT402I, DT402R or DT402D and software version number. It is displayed for a few seconds each time you power on the DT402. 3. The DT402D will then momentarily display the Duplex Group name and radio Channel. 4. Next you will see the power indicator ...
The following chart indicates: Which Digitrax throttle (DT400, DT400R, DT402, DT402R, DT402D, DT500, DT500D, DT602, DT602D, UT4, UT4R, UT4D, UT6 & UT6D) Works with which LocoNet interface throttle panel (Universal Panel-UP3/UP5/UP7, UR90, UR91, UR92, and UR93) Under which types of communication (Tethered, IR Mode, Simplex Radio, or Duplex Radio). Throttle Interface Chart Throttle UP Panel Tethered UR90 Tethered UR90 IR Mode UR91 Tethered UR91 IR Mode UR91 Simplex Radio UR92 Tethered UR92 IR Mode UR92 Duplex Radio UR93 Duplex Radio DT400 Yes Yes Yes Yes Yes No Yes Yes No No DT400R Yes Yes Yes Yes Yes Yes Yes Yes ...
Can I add Radio and IR to my Zephyr Xtra?Yes.Adding radio and/or IR to Zephyr and Zephyr Xtra is the same as adding it to any other existing Digitrax layout or Digitrax Starter Set. Digitrax offers InfraRed, Duplex Radio and Simplex Radio systems for wireless operation. Any combination of these wireless methods can be used on the same layout at the same time.Infra Red Wireless OperationAll current Digitrax throttles are Infrared capable (InfraReady) in that they come from the factory equipped with the IR emitters required to send IR information to LocoNet. To use this functionality, you only need to ...
Adding duplex radio, infrared or simplex radio to your existing Digitrax system is simple because of LocoNet.InfraRedYou probably already own a DT300, DT400, UT4 or DT402 series throttle. All of these are "InfraReady." These all come with two IR emitters pre-installed. All you have to add for IR operation is one or more UR90 Infrared Receivers to your layout. Most layouts require multiple UR90s because the infrared signal is line of sight. This means that your receiver will need a sight path to the throttles.Simplex RadioDigitrax throttles with an "R" at the end of the part number are simplex radio ...
Can I add Radio and IR to my Big Boy?Yes.Adding radio and/or IR to Big Boy is the same as adding it to any other existing Digitrax layout or Digitrax Starter Set. Digitrax offers InfraRed, Duplex Radio and Simplex Radio systems for wireless operation. Any combination of these wireless methods can be used on the same layout at the same time.Infra Red Wireless OperationAll current Digitrax throttles are Infrared capable (InfraReady) in that they come from the factory equipped with the IR emitters required to send IR information to LocoNet. To use this functionality, you only need to add one ...