DB150 5 Amp AutoReversing DCC Command Station/Booster makes your layout more fun to run more trains, manage short circuit shutdowns and add automatic reversing. Used as part of a Super Empire Builder Xtra starter set or seperatly it gives you the capability to run upto 22 locos and 22 throttles. Great for upgrading your basic LocoNet system.
The DB150 has many customizable system operation options that you can set. The DB150's power up defaults are fine for most applications and the DB150 will run just fine right out of the box. These options are provided for those individuals who want more flexibility in setting up their operations. The factory default setting for all DB150 option switches is t or thrown except for 5, 17, 25, 33 and 34 which are closed ("c"). Changing DB150 Option Switches 1. Consult DB150 Option Switch Table to determine which DB150 option switches you want to change. 2. Move the right toggle switch on the ...
Digitrax DB150 Command Station/Booster Power On LED Diagnostic BlinkingSteady on = DB150 is operating as a Command Station/Booster 1/2 sec on / 1/2 sec off = DB150 is operating as a Booster only 1 sec on / 1 sec off = DB150 is in Option (OP) mode, the Option switch is in the OPTN position 2 sec on / 2 sec off = DB150 is in Sleep mode, the Option switch is in Sleep mode Fast pulsing = DB150 is in Program Mode, the Option Switch is in PROG mode. Commands sent in this mode will program decoders that are ...
If the DB150 unit shuts down occasionally due to a track short circuit: 1. Correct the short circuit condition and the booster will resume normal operation. 2. Turning off the booster when a short occurs is not necessary since it will re-start automatically when the short is cleared. If the DB150 unit shuts down frequently: 1. Move the DB150 so that the heat sink has a flow of cool air. 2. Place the DB150 out of direct radiant heat like sunshine or a room heater. 3. Try direct cooling by using a small fan to blow air onto the heat ...
There are times when it is necessary to reset the Super Empire Builder. Because this is a system reset, there are special instructions: There are different levels of system reset. OpSw 36: Clears all mobile decoder information, including locomotive consists. OpSw 38: Clears the locomotive roster (such as when you receive a "slot=max" error report). OpSw 39: Full reset, clears all internal memory states. The factory default setting for all DB150 option switches is t or "thrown" The Initial Procedure 1. Determine which DB150 option switch you want to change, 36, 38 or 39. 2. Move the Mode toggle switch on ...
Q: I recently split my layout in half, with a DB150 acting as a booster powering one side and a DCS100 powering the other. I'm trying to reconnect the bus feeders to the rails, which all worked properly before the split. Now when I reconnect the feeders there is no short indication, BUT when a loco goes over the insulated gap between the two sections, a short occurs. A: This is a common issue when the first booster is added to a DCS100/DCS200 command station. MOST DCS100/DCS200 command stations come from the factory set with Rail A & Rail B connections that are the opposite ...
The DT400 series’ Track Power Indicator and the DB150’s track status indicator show whether track power is on or off. The first time you plug in your DT400 series throttle, track power will usually be off. To run trains, you will need to turn on the track power. Look at your DB150 and/or DT400 series to determine whether the track power is on or off. 1. When track power is off: DB150 TRACK STATUS indicator is off DB150 OFF LINE indicator is on and DT400 series Track Power Indicator is off (Track Power Indicator is a small dot in the top line on ...
The actual track voltage supplied by the DB150 can be adjusted. To do this, you must open the DB150 case (this will not void your warranty). 1. Open the DB150 case. Remove the black screws on the top and bottom of the case and slide the gray front panel off. Be careful to avoid disturbing components other than the ones described below. 2. Locate the small yellow trimmer potentiometer behind the LocoNet B Jack and Scale Switch. 3. Use a small screwdriver to turn the potentiometer clockwise to increase the scale voltage setting. Turn it counter clockwise to decrease the ...
The two "POWER IN" terminals on all Digitrax boosters & command stations are the power input connections. Digitrax recommends the PS514 to power the DC200 and DB150. Set the voltage setting on the PS514 to 16.8v or 19v. The PS2012 can also be used to power the DCS100 and DB150. The "Y" cable provided with the PS2012 has an embedded 5 amp current protection. The PS2012 can also be used to power the DCS200. The "Y" cable is not suitable for use with the DCS200 since it has an 8 amp. output. When powering your layout, make sure that all polarities and ...
The front panel of the DB150 Super Empire Builder has electrical connection points, indicator lamps, LocoNet connections and toggle switches which give status indications, configure and connect the unit for your railroad. Power Input The two “POWER IN” terminals on all Digitrax boosters & command stations are the power input connections. Please see the related articles about power requirements for the DB150. Power Supply Digitrax recommends the PS515 power supply to power the DB150. There are many other transformers and power packs that can supply the input power for the DB150. Check with your Digitrax dealer for suggestions. Most regular ...
The DB150 has 22 “Slots” for locomotive addresses The DB150 command station can run up to 22 loco addresses and throttles at a time. Each of these addresses occupies one of 22 “slots” available in the DB150’s memory. Once those 22 slots are full the system will display the “slot=max” message to let you knot that you need to release some locos if you want to select and run others. The DB150 manages the addresses that occupy slots by assigning different statuses to each decoder depending on how it is being used in the system. This allows the DB150 to ...
If you want to change the address or other settings of your locomotive decoders, you must set up a programming track. It is very important that the rest of your railroad can be isolated from the DB150 and the programming track when you are programming a locomotive. Decoders are programmed when the DB150 command station sends programming information to them through the rails. There are two basic ways of programming decoders. Service mode programming broadcasts a message to all DCC equipped locos that are on the track. Because this is a broadcast method, you will need to set up a ...
Shutting Down the System When you are finished with your sessionDispatching All Locomotive Addresses Some users prefer to “dispatch” or release all addresses active in their system before shutting down. This can prevent unexpected results when you power up the layout again. 1. Turn track power off: Press the PWR Key followed by the N - Key , the Track Power Indicator on the DT400 and the Track Status Indicator on your command station will go off. 2. Move the DB150 command station’s “MODE” switch to the “SLEEP” position. 3. Turn off the power supply to the system. Leaving the ...
If the DB150 beeps 5 times and shuts down briefly and then comes back on again. It is probably being run too close to its pre-set current limit. To solve this problem, reduce the track current load by setting up additional power districts to provide more total power for the layout. In this case excess current consumption may clip or mutilate some outgoing packets to keep the track current within acceptable limits.
The DCS100, 200, 240 and DB150 use several beeps and clicks that can be used as diagnostic tools that will help you debug a number of error conditions. DCS100/200 Audible Sounds 1 Beep DCS100/200 has powered on successfully or has sent a programming command. 3 Beeps A loco address has been "purged" due to non-use. This is informational only and is normal. 4 Beeps Booster short circuit shutdown. Fault Alarm. 6 Beeps Command station already present in system. When two command stations are operating on the same system, you may experience unexpected results. 7 Beeps DCS100/200 CMOS battery low ...
To use the UT2 to program a decoder you must first put the UT2 in Programming Mode. To do this press and hold “RUN/STOP” and simultaneously press “PROG”. The Status LED will now turn a steady orange color indicating the UT2 is now in Programming Mode. Set the locomotive you wish to program on an isolated programming track (See Section 5.2). Make sure that the DB150 command station is not connected to any other part of the layout. If you don’t have a programming track on your layout remove any locomotive you don’t want programmed at this time. Decoders ...
Option switches are used to change the operation of the DB150. Option Switch # Effect on system when Option Switch “c” closed Default OpSw 02 Booster Only override t OpSw 03 DB150’s booster is auto reversing t OpSw 05 Default closed for command station –DO NOT CHANGE- c OpSw 13 Loco purge time extended from 200 seconds to 600 seconds t OpSw 14 Loco purging is disabled t OpSw 15 Purging will force loco to Stop or 0 speed t OpSw 17 Automatic advanced decoder assisted [FX] consists are disabled c OpSw 18 Extend the DB150 booster short circuit ...
How To Turn Track Power On and Off with the DT400 series throttle Turn track power on: Press the PWR Key, then press the Y + Key and the Track Power Indicator on your DT400 series display and on your command station will come on solid. If the track power indicator is blinking, press the Y+ key again to make it solid. Turn track power off: Press the PWR Key , then press the N - Key . The Track Power Indicator on your DT400 series and on your command station will go off. To Exit: Exit PWR mode by pressing the ...
Q: I connect my DT400 to my DCS100 and it works fine, but when I add a DB150 working as a booster the DT400 stops working. What is wrong? A: A number of things may cause this, so you can use the diagnostic features of the DT400 to solve this problem. Experience has proven that the most common LocoNet problem is related to pins 3 and 4. By following this diagnostic procedure, you can narrow down to the source of the problem. Starting with DT400 without a battery [The throttle has no battery for this test to assure it executes ...
Q: I just purchased a used Digitrax set consisting of a DB150, UT2 and a PS515 for a very low price. What do I need to add to bring this up to current standards? A: Because of Digitrax LocoNet, it is easy to add the latest components to upgrade on older starter set. What you purchased was originally called a Genesis Starter Set. The PS515 did not come with it but it is the perfect power supply for the DB150. Your next step depends on what you want to do with your railroad. In this case, the components you have will be ...
These instructions will get you up and running quickly. A full description of all controls and technical reference information are included later in this section of the Tech Support Depot. This section assumes that you are using a new set straight out of the box. If your set is radio equipped, we recommend that you follow this quick start guide without using radio to learn the basics. When you are successfully running your radio throttle tethered to the system, then go to the DT400 series tetherless overview article to learn how to install the radio option. Connect the DB150 to the ...
I have a Zephyr and a DB150. How can I wire the two together so that the Zephyr acts as throttle and the DB150 supplies power? At this this time I have only a single block. The easiest way to handle this situation is to divide the railroad up into two power districts. If one command station unit is more powerful than the other, then the area controlled by the weaker unit (in this case, the 2.5 Amp Zephyr) could simply be a single siding or engine terminal. The Zephyr would then become a booster, supplying power to this small ...
Is it possible to connect my BDL168 across two power districts (Boosters). I envisage using zone 1 & 2, with detection sections 1-8 one one booster (DCS100), with zones 3 & 4, with detection sections 9-16 on another booster (DB150). Will this work? Please refer to the chart below: Note that Pins 1 & A, 6 & F, 13 & P, and 18 & V are identified as "Connection to Booster for Zone *. Each Zone can support up to four detection sections. So, for your application, the DCS100 would be connected to Pins 1 & A and 6 & ...
You can have the power and reliability of Digitrax boosters even if you use a Lenz Command Station. You can use Digitrax boosters to automate reverse loops, too. Digitrax boosters can be used with the Lenz Command Station to provide more power for driving the layout. Many customers are using DB150, DB200, or DB100 series boosters instead of LV100's because the DB150’s & DB100's are very reliable 5 amp boosters with plenty of heat sinking capability to prevent heat related booster shutdows. Equipment needed: 1) A Lenz LZ100 Command Station. 2) A DB150, DB100 or a DB200 series booster. 3) ...
I have a medium/large sized layout with a reversing district. I want to operate 6-10 trains with several operators. I am interested in turnout control, prototypical consist operations and signaling to be added later. I might want a computer added later, too. Which components do I need?You will need a Super Empire Builder Xtra or Super Chief Xtra with additional throttles for the operators and an additional DB150 booster or PM42 for the reversing district. You will also need at least one additional DB150 to provide enough power to run 6-10 trains in N or HO. You can choose and Digitrax ...
If your throttle says "slot=max", this means that the Super Empire Builder's capacity to handle operating locos is full. The DB150 can run up to 22 addresses at the same time. If you have the "slot=max" message, be sure that all locos that are not running have been released from throttles. This will free up room inside the DB150 for other locos to run. A DCS100 command station can run up to 120 locos so, if you are having this problem often, you should consider adding a DCS100 to your LocoNet system. To Release Locomotives 1. Use the throttle to ...
CVs are decoder memory locations that hold loco address, operational configuration and performance settings. Adjusting them to customize the performance of a specific locomotive is one of the main advantages of DCC over DC running. - Doug StuardThese are special storage locations or "pigeonholes" in your mobile decoders. By programming various CVs, you can control each decoder's performance characteristics. CVs store information like the decoder's short address, long address, start voltage, mid-point voltage, loadable speed tables and many more. Once you have programmed these characteristics, the decoders "remember" them until you change them again. Most manufacturers use a similar set ...
Your Super Empire Builder Starter Set contains: The DB150, which is the system’s DCC command station. It generates the DCC signals that control decoders and other devices on your layout. The DB150 is also a DCC booster. Boosters receive DCC signals from the command station, amplify them and put them on the track along with the power from the transformer to run the locomotives. You can have several boosters on your layout to provide additional power to run more locos. Depending upon the set, there is either a DT402 or DT402D (duplex radio throttle), which is the DCC throttle that ...
The DT400 can control Functions 1 - 12.Note: DT400 can access F0-F12 when used with the DCS50 Zephyr or DCS100 Super Chief command station. DT400 can only access F0-F8 when used with a DB150 Super Empire Builder command station.To enter Fn (function) mode:1. Determine which throttle you want to control functions on and make it the active throttle by single clicking the throttle knob or by turning the throttle knob a couple of clicks.2. DT400’s numeric keypad is always active in function mode during normal loco operations. When the mode indicator on your DT400 shows Fn, simply press any number ...
The DT402 & DT400 can program and readback CVs with the DCS100 or DCS200 (Super Chief) or the DCS51 or DCS50 (Zephyr). You must use the programming track for this unless you are using Ops Mode with transponding installed to allow for Ops Mode readback. Infrared and simplex radio throttles must be plugged in to LocoNet to read back CVs & their values. Duplex radio throttles do not have to be plugged in for reading back CVs.Systems with a DB150 command station (Super Empire Builder) are not able to read back CV Values programmed into decoders. To read back CV values: 1. Place the decoder ...
Since many Zephyr and Zephyr Xtra Starter Sets are used on smaller railroads, a natural choice for setting up an automatic reversing section would be an AR1. If you have more than one reverse loop, then the PM42 is a better choice. These automatic reversing strategies will work equally well for any Digitrax system using any Digitrax Starter Set. Alternately for larger railroads, an auto reversing booster such as the DB150 can be used for automatic reversing if the section is large.
Super Empire Builder superseded Empire Builder II Super Empire Builder Included A DT400 throttleA DB150 Command Station/BoosterA UP5 Universal PanelA Short LocoNet CableInstruction Manuals
Note: Upgrading to Digitrax from Lenz doesn't have to mean purchasing all new equipment! This app note shows you how to salvage some of your Lenz equipment when you move up to Digitrax!
It means just what it says. "This Product Conforms To All Applicable NMRA Standards." An NMRA Conformance Seal is NOT an endorsement by the NMRA. It is NOT a guarantee by the NMRA or by the manufacturer. It is merely a statement that a particular product conforms to a particular test set up and administered by NMRA volunteers to assess whether, in their opinion, the product conforms to a particular NMRA Standard. Interpretations of this statement vary widely depending on whom you ask for clarification.The Real Issue is InteroperabilityInteroperability means that you don’t have to worry about a single source ...
We are a LARGE club layout. We have several reversing districts, 25 operators and run 30 trains at a time. We want computer control, turnout control, signaling. You name it, we've got it. What equipment do we need to run this layout?You probably need the Super Chief Xtra Set with additional throttles, boosters, mobile & stationary decoders & detectors.A typical HO layout of this size would need approximately 5 boosters & power supplies to provide enough power to run 30 engines. The DCS100 command station/booster will be one of these boosters so; you would need 4 additional DB150 series boosters. You will ...
The DS64 is a powerful stationary decoder. If you have tried to program this stationary decoder and are having problems, there are several things that you can do before contacting Tech Support for further help. Is the DS64 receiving enough power? The DS64 can be powered in several different ways. Although it is possible to power the DS64 from track power, this has been a source of problems for many operators due to low voltage. This typically arises on a railroad that is using power in excess of the capacities of its power supplies. Have you programmed all four addresses ...
DT400 is designed to maintain a close similarity in function & feel with Digitrax DT300, DT200, & DT100 series throttles. This family resemblance makes it easy to add new throttles to your Digitrax Command Control System and be able to use them in ways similar to the existing throttles that you are already used to. DT400 can be used with any Digitrax LocoNet System or other LocoNet compatible DCC system. User friendly Multi-line Backlit LCD with easy to read icons and messages. Prompts in the display guide you every step of the way. To make operation easy and ...
Q: How do I program the PM42 Option Switches (OpSw) with a DT400 throttle? A: The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSws is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the DT400 series throttle with any Digitrax command system. 1) Connect the PM42 to a DCS50, DCS51, DB150, DCS100, or DCS200 with a standard LocoNet cable. 2) Connect the PM42 to an external power source; Digitrax ...
Q: How do I program the PM42 Op Switches with a DT300 throttle? A: The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSws is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the DT300 throttle with any Digitrax command system. 1) Connect the PM42 to a DB150, DSC050, DSC100 or DSC200 with a standard LocoNet cable. 2) Connect the PM42 to an external power source; Digitrax recommends the ...
Q: Can you have two command stations on the same layout? A: No. If you try and run with two command stations you will experience what we usually refer to as "shocking, horrifying results." Two command stations on a single layout is often a problem with modular layouts. You can disable the command station capability in Digitrax Command Station/Boosters so that you can use them as boosters only to add more power to your layout.For the DCS100 to disable command station mode:1. Set Op switch 2 to "c" 2. Set Op switch 5 to "t" 3. Set it to auto ...
Q: Your recommendation is to have a DB150 booster at no more than 50 foot intervals. Will one booster handle all track in that 50 foot area, i.e. a passenger terminal throat with many turnouts and switches? A: The "50 foot intervals" applies to the maximum distance which boosters can be located from each other. This is a conservative recommendation. You should consider how much power will be consumed in a district when locating boosters around the layout. If your power district is a single track railroad stretching over hundreds of feet of linear distance, boosters should be placed at 50 ...
The DT402 & DT402's screens are an LCD (Liquid Crystal Display) that is designed to show you what you are controlling with the throttle. It also facilitates programming and other features of the LocoNet system. 1. The handheld has two throttles called the left throttle (L) and the right throttle (R).2. There are two direction indicators. One for the L throttle and one for the R Throttle. If the direction indicator is lit, and there is smoke over the loco icon there is an address selected on that throttle.3. The direction indicator with blinking smoke indicates which throttle is currently active. The ...
Before sending your Digitrax Command Station or Booster in for repair try these simple steps to see if you can “bring it back from the dead” and save a possible trip to the repair shop.1. Nothing is respondingIf there are NO LEDs lit on the front panel of the Command Station or Booster: Check the power supply to the unit to make sure that it has not been knocked loose in the power socket and that the socket is powered. Check the connections from the power supply to Track A and Track B connections on the front of the unit ...
The DZ121 was discontinued in 2002. There were some interoperability issues with Easy DCC, MRC and Lenz. The exchange offer is no long valid. This article is still published for reference only.At that time, Easy DCC, Lenz and MRC users could return DZ121's to Digitrax for no charge replacements that will work on their systems. There was no reason for Digitrax, Wangrow or NCE users to replace any DZ121 decoder unless they wre having problems.The text at that time:For Easy DCC and Lenz users who are having problems: To determine whether your DZ121 should be returned, read back CV07. A ...
I'm helping a friend rewire an existing layout from analog to digital. You might be familiar with the layout, it is the original Clinchfield layout that Model Railroader built back in the late seventies, believe it or not. The layout, of course, is blocked for analog through DPDT switches which have been eliminated. I was able to repair the wiring back to original using the drawings that MR printed. The layout uses common rail wiring, this is what I have to work with, and to rewire using home run wiring would be a MAJOR rework, not doable. I was able ...
Ops Mode programming, also known as "Programming on the Main" lets you change the configuration of an individual decoder while the locomotive is on your railroad without having to move it to the programming track.Operations mode programming lets you program CVs in DCC locomotives equipped with Ops mode capable decoders while they are on the mainline. A typical use for Ops mode programming would be to change the acceleration rate (CV03) or the deceleration rate (CV04) of your locomotives to simulate the weight and braking capability of the train to compensate for changing the number of cars or power units on a ...
There is a numeric keypad on the DT402/DT400 throttle. The numeric keys on the keypad are primarily related to the throttle mode shown in the LCD’s mode indicator area, but can be used for numeric entry and function control in other modes. For example, when the command station is in the Function Mode Fn, the numeric keys are used for function control. When the command station is in the Locomotive Mode,Lo, the numeric keys are used to enter loco addresses. When the command station is in the Switch Mode is Sw, the numeric keys are used to enter switch addresses.In ...
There are 1024 different CVs that have been defined to handle many characteristics you might want to use for your locomotives. Your decoder manual has a complete listing of CVs that are available in specific decoders, what they do and suggested values for each CV. 1. Place the decoder equipped locomotive you want to program on the programming track. If you are using operations mode programming, the loco you want to program can be anywhere on the layout but it must have a decoder that is capable of ops mode programming installed. 2. Enter Program Mode by pressing the PROG ...
In addition to the locomotive address, there are different Configuration Variables (CV's) that have been defined to handle many characteristics you might want to use for your locomotives. These include operational characteristics such as acceleration, headlight functions and others. The manual for each decoder type has a complete listing of CVs that are available in specific decoders, what they do and the suggested values for each CV. Simpler decoders have few CVs while advanced decoders may have many different CVs 1. Place the decoder equipped locomotive you want to program on the programming track If you are using operations mode ...
Follow these simple instructions to determine the best location/s on your layout for installing your UR panels for the best possible infrared or radio reception. With LocoNet, you can use Infrared, Duplex Radio and Simplex radio individually or in any combination on your layout.You'll need to be able to observe whether your command station is receiving commands from the UR panels when you are installing infrared or radio receivers and transceivers. Your Digitrax command station makes it easy to determine when the system is receiving a signal and when it is not. You can observe the NET LED and the Track Status Indicator or your ...
The answer to this question applies to all Empire Builder sets including Super Empire Builder XtraQ: I have just purchased a Super Empire Builder set. My expectations are for it to operate an N-Scale switching layout right now with future expansion to a larger N-Scale layout. I am a little confused as to which power supply I would need at this time. I am reading about power supplies and inline fuses, all of which is a little overwhelming to me as I am getting back into the hobby. Can you recommend which power supply will be better for me as ...
Programming is the process of setting the configuration variables (CVs) in your decoder to the appropriate values that will make the locomotive perform the way you want it to. The first CVs that most people change are those that set the locomotive decoder's address. The mobile decoder in your locomotive usually comes pre-porgrammed to a factory default address of "03". Once you add a second locomotive, you will want to change the this new locomotive to another address. Not doing so will result in both locomotives operating at the same time when you send commands to address 03.Likewise, there are a ...
Q: I read in the February 2008 "Scale Rails" on page 11 that I need to add some "High Frequency Filter" gizmos on my layout to make my trains run properly. I have been using Digitrax equipment for 12 years, do I need to make these changes? A: We do not feel that this is necessary. With modern, well designed decoders, almost any combination of transmission-line ringing and other mismatch effects described in this article are completely filtered and ignored by the decoder. This is a superior solution rather than trying to design filters for unpredictable limiting cases of wiring ...
Duplex Radio Throttle do not need to be plugged in to LocoNet to Program Decoders. Simplex Radio & Infrared throttles must be plugged in to LocoNet to program CVs on the programming track. Ops Mode Programming can be done without plugging radio throttles in to LocoNet. IR throttles must be plugged in for Ops Mode Programming. 1. Be sure that only the loco you want to program is on the programming track. If you are using operations mode programming, the loco you want to program can be anywhere on the layout but it must have a decoder that is ...
This document outlines the power requirements for Digitrax LocoNet accessories. To simplify wiring, Digitrax recommends providing individual power supplies for like accessories. For example a power supply or power buss which only powers the PM42s. A power supply or power buss used solely to power multiple DS64s. UR9x and UP5 panels can be daisy chained provided adequate current is provided to properly power all the panels. Through the use of individual power supplies, the chance of Ground Loops or sneak paths back to ground is minimized. Using individual power supplies will also make troubleshooting much easier. Many Digitrax LocoNet ...
Zephyr Xtra Super Empire Builder Xtra Super Chief Xtra Command Station DCS51 DB150 DCS100 Current Rating 3 Amps 5 Amps 5 Amps or 8 Amps Throttle DCS51 DT402 DT402 Throttle Controls Single Knob, Direction Switch Dual click encoder throttles Dual click encoder throttles Function Control F0-F29 F0-F29 F0-F29 Keypad Full Numeric Keypad Full Numeric Keypad Full Numeric Keypad Display Large LED Multi-line Backlit LCD Multi-line Backlit LCD Throttle Capacity 20 22 120 Loco Capacity 20 22 120 Loco Address Range 00-9000+ 00-9000+ 00-9000+ Stationary Address Range 01-999 00-999 00-999 Turnout Position Reporting Yes, last command sent Yes, last ...
The PS615 is the Digitrax recommended power supply for the DCS240 in 5 amp mode. For operations at 8 amps the PS2012 is the recommended power supply. When using the PS2012 special wiring considerations need to be used when powering both the DCS240 and legacy boosters from the same PS2012. Leagacy boosters are defined as the DCS100, DCS200, DB150, DB200 or DB100. Please see the separate article “Powering your DCS240 with a PS2012” and the additional notes below. The DCS240 may be powered either using the barrel plug connector or the screw terminals labeled “+” and “- “. The barrel ...
Before sending your Digitrax mobile decoder in for repair try these troubleshooting steps to see if you can “bring it back from the dead” and save a trip to the shop and possible repair charge. As with troubleshooting anything, begin checking what could be wrong methodically. Write down your observations as you work through the list to solve the problem.The most common "repair" problem we see in our repair department is decoders that are programmed incorrectly.Many decoders we receive for repair have been programmed with CV values that cause them to seem to have a problem. The good news-bad news ...
Zephyr Xtra Super Empire Builder Xtra Super Chief Xtra Command Station DCS51 DB150 DCS100 Current Rating 3.0 Amps 5 Amps 5 Amps or 8 Amps Throttle DCS51 DT402 DT402 Throttle Controls Single Knob, Direction Switch Dual click encoder throttles Dual click encoder throttles Function Control F0-F28 F0-F28 F0-F28 Keypad Full Numeric Keypad Full Numeric Keypad Full Numeric Keypad Display Large LED Multi-line Backlit LCD Multi-line Backlit LCD Throttle Capacity 20 22 120 Loco Capacity 20 22 120 Loco Address Range 00-9000+ 00-9000+ 00-9000+ Stationary Address Range 01-999 00-999 00-999 Turnout Position Reporting No Yes, last command sent Yes + actual ...