Cost Effective LocoNet Occupancy Detections, LocoNet Occupancy Detector For 16 Detection Sections
BDL16 was released in 2000 and was replaced by BDL162 in 2002. An update kit was available from BDL16 to BDL162. BDL162 was replaced by BDL168 in 2004. No update kit was offered because the circuit board was completely re-engineered.
How do I add a heatsink to my BDL162 for large scale operations?The BDL162 design does not include a provision for a heatsink. There is not a kit available for adding on a heatsink, but you can make your own if you believe it necessary for your system. The following drawing will provide the correct measurements to produce a heatsink that will slip in between the two rows of rectifiers on the BDL162 Circuit Board. This will raise the current handling capacity but we do not know by how much.Cut the heatsink from .05" thick aluminum or brass sheet stock, ...
How do I Increase BDL162 Detection Section Threshold SensitivityThe BDL162 has Option Switch settings to control detection sensitivity. The factory setting is OpSw19=t for a threshold sense for DCC occupancy of approximately 22 Kohms minimum. Changing OpSw19=c will set the threshold to 10 Kohm minimum. See the BDL162 instruction manual for details on setting the Option Switches. These settings will accommodate most layouts, though there may be circumstances when a higher threshold is desired, for example, in a high moisture environment or with G scale operations outside.To raise the threshold even further resistors can be added into the wiring between ...
The BDL168 manual states that 2 RX4's can be connected but it only shows how to connect one of them on Aux 2. How is the second RX4 connected? The RX4 is a 4 Zone Transponding Receiver Add-on for BDL16 series occupancy detectors. Each RX4 is made up of 4 RX1 sensors, a ribbon cable and a connector that lets you plug the unit into a BDL16-series detector. The earlier BDL16 and BDL162 occupancy detectors had the capacity for hosting one RX4. BDL16 & BDL162 boards are labeled with AUX1 & AUX2. Only the AUX2 connection should be used for ...
1. Install BDL16 series occupancy detector(s). BDL16, BDL162 and BDL168 occupancy detectors can be used together on the same layout.2. Add RX4 transponder receivers to the zones you want to set up for transponding. (You won't need to cover every detection section on the railroad for effective coverage and reporting. Some areas will be detection only sections while others will have full transponding as needed.) Use either two RX4s with your BDL168 to set up 8 transponding zones or use one RX4 if you only need 4 transponding zones.3. All current production Digitrax decoders are transponder equipped. If you have decoders ...
Do you have a recommend wiring procedure for the 44-pin edge connector on the PM42 and SE8C?PM42, PM4, BDL168, BDL16, BDL162 & SE8C use a 44-pin edge connector. Connecting wires securely to this connector requires soldering skills. For connections to the 44 pin connector, Digitrax recommends using 16 gauge stranded wire. For all other soldering connections, Digitrax recommends 14 gauge (AWI) stranded wire for electrical connections on your railroad. 1. Use individual short lengths of 16 gauge wire to connect to the 44 pin connector. 2. Strip and tin both ends of the wire. 3. Bend one end into ...
RX4 / BDL168 Hookup Worksheet BDL168 #_______ Address:________ Description______________________________________________________ Aux Power:_______ Standard BDL162 Configuration Advanced Detection Section Wiring: Transponding Method________________________________ Section Pin # Named Detection Section Description ZONE A Power In 1 1 2 Power 2 3 District 3 4 4 5 In Out Alternate Zone Comments ZONE B Power In 6 5 7 Power 6 8 District ...