Mobile Decoders (Locomotive Decoders) -> Decoder Installation General -> Decoder Installations O, S, G Scales
DG583S - Function Outputs 1. Function outputs are rated at 2 Amps each. Do not exceed the decoder’s 5 Amp total output rating. This total includes the motor current and total of all function output currents.2. To use a function output with an inductive(coil) type load, see the Digitrax Decoder Manual for more information to avoid damage to the decoder.3. See the Digitrax Decoder Manual for full details of wiring 12-16V lamps, 1.5V lamps, and LEDs. Lamps that draw more than 80 mA when running require a 22 ohm 1/4 watt resistor in series with the directional light function lead ...