You are viewing all articles in Layout Power and Wiring -> Powering Your Layout (including subcategories). To further filter by subcategory, select from below.
Q: If my layout is experiencing short because of a thrown switch, how can you reset the switch using DCC? Many Digitrax operators use the PM42 Power Manager, which provides protection to four power sub-districts. One segment of the PM42 is used to control track switch power, with the balance being used for train power. When the inevitable happens and a train runs into a thrown switch, resulting in a short, the PM42 shuts down the track power in that segment, while the track switch power is maintained, allowing you to throw the offending switch. Because the PM42 isolates only ...
The term smooth DC is used to describe the power provided to the layout by conventional model railroad power packs (analog transformers). Traditional model railroad power packs convert household line current into 12-18 volt current to power your model railroad. Voltage is supplied to the track, and as the voltage increases, the speed of the locomotive's motor increases, which makes it run down the tracks at faster speeds. Some power packs put out only AC (alternating current), while others put out DC (direct current) and AC (for accessories such as track switches and building lights). AC powered trains tend to ...
The track power indicator on your DT400 shows whether track power is on or off. If the track power indicator is lit then track power is on. There is also a Track Power indicator on your command station.To Turn Track Power On:If the Track Power Indicator is not lit, turn track power on as follows:1. Press the PWR Key2. Press the Y + Key and the Track Power Indicator on your DT400 display and on your command station will come on solid. If the Track Power Indicator is blinking, press the Y+ Key again to make it solid and turn ...
I have read that the amperage of the power supply should match the amperage rating of the booster / command station. Yes, from the standpoint of putting more than 8 Amps of power into an 8 Amp Chief is not going to make a difference since only 8 Amps is going to come out. Less than 8 amps in is only going to result in that same amount (roughly) out; thus, a 5 Amp power supply will only yield 5 Amps out, even though the system is rated at 8 Amps. The DCS200 Super Chief is rated at 8 amps. ...
This H0-scale railroad track plan first appeared in the Atlas Model Railroad Company's book "Six Railroads You Can Build", written by John Armstrong and illustrated by Tad Stepek. This book was first published in 1958 and has been reprinted several times. A classic bowl of spaghetti, the Transbay Interwoven has two reversing loops and a turntable. DC Control For DC operation, Atlas specified three Atlas Controllers (for the reverse loops and the turntable), two Atlas Selectors (to control eight track segments) and ten controllers for the railroad's turnouts. DCC Makes Things Simple With DCC, the wiring of this railroad is ...
I have purchased an LNRP, UR90, and 4 UP5s. I have noticed the LNRP seems to have a solder point between the two LocoNet jacks as the UR90 and UP5.Can all of these be connected to the same 12 volt power supply? No. It is important that each LNRP has its own power supply. As noted in the documentation that comes with the unit, "the LNRP drives the power and Railsync signals on the standard LocoNet cable segments, so each LNRP should have a DC input of +12V to +18V at up to 250mA supplied on the side DC power ...
Fortunately, most DCC railroad wiring is very simple and easy to install. One critical point for any DCC system is power consumption, how much power an individual Booster is able to deliver. The available power is measured in terms of Amperes or Amps. The higher the Amp rating, the more power is available to run your layout.Amps have often been compared to water pressure in a pipe. When the pressure is low, turning on one faucet will draw from that water pressure. As more faucets are opened, the water flow from each faucet drops. One solution is to turn off ...
You can add a second Zephyr to add more power and an additional throttle on the DCS50 and two additional Jump ports for using DC power packs to control DCC locomotives. You will need to change Option Switch 02 to c (Closed) on the second (and any additional DCS50s you might choose to add to the layout as well). The diagram below shows you how to do this.
The two "POWER IN" terminals on all Digitrax boosters & command stations are the power input connections. Digitrax recommends the PS514 to power the DC200 and DB150. Set the voltage setting on the PS514 to 16.8v or 19v. The PS2012 can also be used to power the DCS100 and DB150. The "Y" cable provided with the PS2012 has an embedded 5 amp current protection. The PS2012 can also be used to power the DCS200. The "Y" cable is not suitable for use with the DCS200 since it has an 8 amp. output. When powering your layout, make sure that all polarities and ...
From the start, the Texas & Southwestern was built with DCC in mind. The T&SW was built from the ground up by an individual with considerable model railroad experience, but an issue arose that defied explanation. The T&SW was meant to be operated with a DCS50 Zephyr, and the layout support structure was enlarged slightly to fit the Zephyr into one corner of the railroad. As it turned out, the cozy corner space for the Zephyr turned out later to be a bit too cozy. The bottom of the Zephyr has ventilating slots to help cool the unit’s electronics. As ...
Can I combine the power input requirements for PM42's with other units for economy?Digitrax recommends each PM42 module to have its own seperate power source. The criteria for choosing a power supply for the PM42 is any power source that can deliver 12-15V AC or 13.8-15V DC with a minimum of 125 ma. The Digitrax PS14 meets the minimum power requirement of a PM42.It is possible to power more than one PM42 from a single power source. When powering multiple PM42's special care must be taken to insure identically phasing of all PM42's and ample current availability to power all ...
This section discusses the installation of the physical wiring of the Texas & Southwestern. Underneath the completed Texas & Southwestern are various wires and cables which allow you to operate your railroad. Initially, seeing all these wires can be intimidating, but as you will note, they have been grouped and bundled so that identifying the individual wires is easy. There are two groups of wires under the railroad; one group, the power bus, delivers power to the tracks and to the stationary decoders that operate the track switches. The other group of wires is the black cable for LocoNet and ...
My PM42s seem to correctly trip on track shorts and auto-reverse reliably, but the power briefly drops out during these events, and when the PM42s attempt a fault recovery into a persistent short circuit, why is this?No power on earth can stop the track voltage of the booster from collapsing to a low value when a true short circuit is present. This is simply Ohm’s law in action!Actual track voltage seen depends on: the loop resistance of the short circuit, the current capacity of the booster and power supply and whether the Booster employs "smart" fault detection and recovery along ...
Use a throttle to change the PM42's Option Switches 01, 02 and 09 as detailed in the PM42 instruction manual. The PM42's trip current threshold can be set at a value from 1.5amps to 12 amps. Always use the lowest possible setting, consistent with good operation and reliable short circuit detection and recovery. Higher current settings are not "better." We ship the PM42 with a moderate current trip threshold of 3amps so it will work on most DCC boosters and layouts with no changes.This is because some boosters cannot supply enough current with the track feeder resistance to reliably allow ...
Q: I have three engines lashed together. The sound is coming through . However when I turn the knob there is no response. The engine in the window is blinking and there are two stationary dots above A: If you are using a DT300 series or DT400 series throttle, make sure that the Track Status Indicator dot in the upper right of the display just below the right throttle knob is on solid. If it is not on at all Track Power is OFF. If it is blinking, Track Status is in Idle and the throttle knobls will not move the locos. To ...
Good DCC practice means good planning for the electrical needs of the railroad. Here, we talk about the power needs of the Texas & Southwestern. Anticipating Power Consumption The core of the Texas & Southwestern's DCC control system will be the DCS50 Zephyr, which is very appropriate for a small railroad. Zephyr has 10 "slots", memory locations in the command station each holding an active decoder address. Rated at 2.5 Amps, the Zephyr should also be enough to handle the power needs of the railroad, but if more power is needed, then T&SW can easily be expanded with an additional booster ...
To stop everything on the layout, press the PWR Key followed by the N - Key while the track power is on. This will turn track power off and will cause all locos to stop. Press the PWR Key followed by Y + Key again and the locomotives will start running again at the same speed they were running prior to STOP mode. To exit PWR mode, press the PWR Key or the EXIT Key.
The DT400 series’ Track Power Indicator and the DB150’s track status indicator show whether track power is on or off. The first time you plug in your DT400 series throttle, track power will usually be off. To run trains, you will need to turn on the track power. Look at your DB150 and/or DT400 series to determine whether the track power is on or off. 1. When track power is off: DB150 TRACK STATUS indicator is off DB150 OFF LINE indicator is on and DT400 series Track Power Indicator is off (Track Power Indicator is a small dot in the top line on ...
Digital Command Control (DCC) has specific electrical requirements that must be provided for your layout control system to operate properly.Input PowerAll DCC systems require an external power supply. Digitrax manufactures several power supplies for our command stations and boosters: The 3 Amp PS415 (the Zephyr Xtra power supply) The 5 Amp PS515 for all Digitrax 5 amp command stations and boosters The powerful 20 Amp PS2012 can be used for multiple 5 and 8 amp command stations and boosters Additionally, the PS14 is available to power various other devices for your railroad. Digitrax strongly encourages you to use our power supplies to insure satisfactory ...
The DB200+ is the 8 amp booster. It has NO command station capability. This booster was designed for adding power to layouts that run lots of locos and for large-scale layouts where power requirements are heavy.DB200+ Control PanelNOTE: DB200+ front panel graphics may vary from those shown here. Internally the booster is the same. These instructions are written for both versions of graphics as well as the DB200+ OPTO optoisolated version of the booster. About the Green Jumper WireEvery DB200+ is shipped with a green jumper wire on the front panel Booster Terminal Plug connecting Synch & Ground or ‘Config ...
How To Turn Track Power On and Off with the DT400 series throttle Turn track power on: Press the PWR Key, then press the Y + Key and the Track Power Indicator on your DT400 series display and on your command station will come on solid. If the track power indicator is blinking, press the Y+ key again to make it solid. Turn track power off: Press the PWR Key , then press the N - Key . The Track Power Indicator on your DT400 series and on your command station will go off. To Exit: Exit PWR mode by pressing the ...
I am building a layout that will have two completely separated track plans; not connected with each other by any track. I am running one layout with a Super Chief that has one AR1 reversing controller. I would like to run the second layout with the same throttle. It will have a reversing loop, as well as a turntable. I have thought that I could run the second layout with a booster and a couple of AR1s or PM42.My questions is, will I have any problems with the reversing loops, especially if one on each layout is triggered at nearly ...
If the DB150 unit shuts down occasionally due to a track short circuit: 1. Correct the short circuit condition and the booster will resume normal operation. 2. Turning off the booster when a short occurs is not necessary since it will re-start automatically when the short is cleared. If the DB150 unit shuts down frequently: 1. Move the DB150 so that the heat sink has a flow of cool air. 2. Place the DB150 out of direct radiant heat like sunshine or a room heater. 3. Try direct cooling by using a small fan to blow air onto the heat ...
I was planning on purchasing the Digitrax Super Chief Radio 5 amps but several members in the club told me to buy them Super Chief Radio 8 amp for my HO Layout. They said you will need the power when you start expanding.Question:Is it ok to use the 8 amp version for my HO layout?Answer:Yes it is fine to use 8 amp Digitrax boosters on your HO layout. The choice between 8 amp and 5 amp command station/boosters, it is a question of how much power your railroad is likely to consume on your railroad as it is built today. ...
The PWR Key is used to enter power mode for turning layout power on and off. Once you press this key, you will be prompted to use the Y+ key to turn power on or the N- Key to turn power off. The PWR Key is also used to turn on and off the flashlight feature. The flashlight LED will be on as long as you hold down the PWR Key.
Regulated power supply delivers more power with less heat for more efficient booster operation. Operates up to 4 Five amp boosters. Scale selectable for use with N, HO or large scale. DC Ammeter. On/Off Switch. Integral cooling fan. Design coordinated for use with Digitrax products. One "Y" Cable (P/N YC52) Included for convenience with dual 5 amp protected outputs All secondary devices must be properly fused on their power input leads for their rated capacity. For example if you intend to use the PS2012 to drive a 5 and an 8 amp booster, you must input fuse these devices for ...
Do I need an additional booster if I run isolated sections through a PM42 or can I use one Zephyr? This is a small layout design (5X9) and looking to make it as simple and safe as possible.This is really a question of how much power your railroad requires. You don't state what scale you are operating in, so a 5x9 in H0 might only have three or four locomotives, while a 5x9 in N-Scale might have fifteen or twenty locomotives.Initially, you will be making an estimation based upon your power requirements and the output power of the 2.5 Amp ...
The DT400 display LCD includes a small star shaped dot which indicates the status of the track power. No indicator = System track power is OFF (Press PWR followed by N-)Indicator On Steady = System track power is ON (Press PWR followed by Y+)Blinking Indicator = System is in “STOP” and track power is ON (Press PWR followed by Y+ and Y+ again)