LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet compatible devices are designed to work together on the network, and in some cases can also accept DCC commands from the track, but often go beyond the scope of simple DCC train control. LocoNet is a peer-to-peer Ethernet type multiple access network. Because of its design architecture, it is very robust and powerful. Layout implementation is simple and wiring is free form with minimal limits. LocoNet is designed to run an unshielded 6 conductor ribbon cable. Digitrax recommends using flat, six-conductor telephone wire ...
Q) You are offering a Loconet Repeater Module LNRP. Is it an RailSync Booster, too? There is no description in the PDF-File about this attribute. A) The LNRP boosts (and separates) the Railsync "Standard" outputs from the master command station ("Protected" Railsync), so if there is a problem with this separated "Standard" Railsync copy, the master Command Station is unaffected along with other devices like track boosters that need good Railsync copies. This boosted Railsync is also over-current protected and the LNRP will turn off an overloaded "Standard" Railsync and automatically retry re-powering, so when the fault clears the "Standard" ...
I have purchased an LNRP, UR90, and 4 UP5s. I have noticed the LNRP seems to have a solder point between the two LocoNet jacks as the UR90 and UP5.Can all of these be connected to the same 12 volt power supply? No. It is important that each LNRP has its own power supply. As noted in the documentation that comes with the unit, "the LNRP drives the power and Railsync signals on the standard LocoNet cable segments, so each LNRP should have a DC input of +12V to +18V at up to 250mA supplied on the side DC power ...
Installation: Figure 1 shows the general arrangement for connecting one or more LNRP's to configure a LocoNet based system for operation. Note that the LNRP's drive the power and Railsync signals on the "standard" LocoNet cable segments, so each LNRP should have a DC input of +15V to +18V at up to 250mA supplied on the side DC power jack. Note that the shaded cable connections are made from the protected network side connections of the LNRP units to the components that are on the "protected" or high reliability part of the System. The other solid cable connections are the ...