If Zephyr DCS50/DCS51’s display shows FuLL this means that it has reached the limit of 10 (20 for the Zephyr Xtra) locomotive addresses that it can manage at one time. If you want to select additional addresses, you will need to release one or more loco addresses before you will be able to select other locomotives to run.The DCS50/DCS51 runs a “purging” routine that helps eliminate addresses that have not been used for a period of time to make slots available for running other addresses.If you see this "FuLL" message while you are operating, you can release locos that you ...
The DCS100 uses several beeps and clicks that can be used as diagnostic tools that help you debug a number of conditions.
DCS50 Zephyr has ten "slots" available for train control. When you are finished running a locomotive address, release it from your throttle so that it is available for other throttles to select and run and so that your command station will have room to run other addresses.To release an address from a throttle:1. With the loco address selected on the throttle, use the Throttle Knob to set the locomotive’s speed to STOP.2. Press the LOCO key to release the address from your throttle immediately. The address will begin to flash in the display.3. Press the EXIT key to dispatch the ...
If your throttle says "slot=max", this means that the Super Empire Builder's capacity to handle operating locos is full. The DB150 can run up to 22 addresses at the same time. If you have the "slot=max" message, be sure that all locos that are not running have been released from throttles. This will free up room inside the DB150 for other locos to run. A DCS100 command station can run up to 120 locos so, if you are having this problem often, you should consider adding a DCS100 to your LocoNet system. To Release Locomotives 1. Use the throttle to ...
The DCS100 automatically shuts down when the heat sink temperature rises to around 45 to 50 degrees Celsius and the OFF LINE indicator will glow red. The DCS100 automatically resumes operation when the heat sink cools down to approximately 40 degrees Celsius. The OFF LINE indicator will also be lit when there is no track status. This is normal and you should not be alarmed.
The TRACK STATUS indicator shows that there is voltage on RAIL A & RAIL B terminals. The color indicates the type of signal: If it is orange the track is getting DCC signals with no analog zero stretching. If the color is green or red then a stretched zero signal is being used to operate a conventional locomotive. When zero stretching is present, the DCC decoder equipped locomotives will read their digital commands normally and perform as commanded. If the Track Status LED is not lit there is no voltage on the track, the track power to the DCS100 may ...
Q: I have a Digitrax Chief system. I wired the programming track as per the manual, using PROGA and PROGB outputs on the DCS100. I turned on the system and checked the track voltage with a Tony Trains RRamp meter, the mainline read 14.2 volts. The programing track did not read anything. I then checked the two wires coming from the DCS100 and they did not have any readable signal. A: The programing track connected to PROG A and PROG B will NEVER have track power on except the very instant the program message is sent. So, you would not ...
If you are NOT plugged into a LocoNet port1. Use the 4 rotary address selector knobs on your UT4 to dial up the 2 or 4 digit address of the locomotive you want to run. To enter a 2-digit addresses, set the first two selector knobs to 0 and enter the two digit address on the 2 address selector knobs on the right hand side of the throttle (for example 0025).2. Plug the UT4 into any LocoNet port and automatic selection occurs.3. A Green Status light confirms that selection has been done successfully - You’re off and running!4. A Red Status light means the loco is ...
If the DB150 beeps 5 times and shuts down briefly and then comes back on again. It is probably being run too close to its pre-set current limit. To solve this problem, reduce the track current load by setting up additional power districts to provide more total power for the layout. In this case excess current consumption may clip or mutilate some outgoing packets to keep the track current within acceptable limits.
When you are programming decoders, there are a few error messages you may encounter.There are many causes for these error messages but most can be solved by checking the following:1. Be sure the programming track is connected properly to the DCS50.2. Be sure a decoder is correctly installed in the locomotive with all motor and pick up connections made correctly.3. Be sure the loco with decoder correctly installed is making electrical contact with the programming track and that it remains in contact with the programming track until programming is complete. Check to see if the track is clean and the ...
The NET indicator is a red LED that displays information about what the DCS100 sees on LocoNet. When your layout is wired correctly and LocoNet is operating properly, the NET indicator will be on and it will flicker off any time a good LocoNet message is detected by the DCS100. The table below explains the patterns you will see for this indicator.
Digitrax command stations have Option Switches that care used to customize their operation. Command Station option switches should not be changed unless you fully understand what you are trying to accomplish. Information on these Option Switches is included in each command station's manual.Be sure that you are changing the correct Command Station Option Switches as the unit can be crippled by closing the wrong switches. NEVER CLOSE OPTION SWITCH #1!!Clearing your Command Station's Mobile Decoder SlotsMost command station problems are caused by filling up the command station's available slots by the following:1. Operators failing to zero the speed of unused ...
Does your throttle say slot=max ?This means that the system's capacity to handle operating locos is full. The DCS100 can run up to 22 or 120 addresses at the same time. If you have the slot=max message, be sure that all locos that are not running are released from throttles or set DCS100 OpSw 44 to closed to increase the number of address slots available to 120. The DCS100 command station that comes with all Genesis, Empire Builder and Chief series starter sets are set with a factory default of 22 slots. So, once you begin to operate significantly more locos, you may need to ...
Stealing A Locomotive AddressDigitrax systems do not allow more than one user to select and run the same locomotive address unless the loco is “stolen” (or shared) by the new user. When an address is receiving commands from more than one throttle, it may seem to be out of control.Stealing is a safety interlock that prevents operators from automatically taking control of locos that are already selected and being run on another throttle. Occasionally you may need to override this interlock to gain control of a loco. This override is called stealing and will result in having a single loco ...
If the DB200+ booster shuts down frequently: 1. Move the DB200+ so that the heat sink has a flow of cool air. 2. Place the DB200+ out of direct radiant heat like sunshine or a room heater. 3. Try direct cooling by using a small fan to blow cool air onto the heat sink. 4. Lower the track load current. 5. Reduce the input voltage from the transformer. If the DB200+ beeps 4 times and shuts down briefly and then comes back on again, it is probably being run too close to its pre-set current limit. To solve this problem, ...
A “Busy” message during programming means that the system is temporarily busy. Simply try the task again. When the system is no longer busy, you will get a “Good” response. A “Fail” message during programming means that there is a problem with the locomotive on the programming track. Check to be sure the loco's wheels are making good contact with the programming track. Make sure that the decoder is properly installed in the locomotive. Make sure the connections to the programming track are secure. Make sure the programming track is powered.
The DB150 has 22 “Slots” for locomotive addresses The DB150 command station can run up to 22 loco addresses and throttles at a time. Each of these addresses occupies one of 22 “slots” available in the DB150’s memory. Once those 22 slots are full the system will display the “slot=max” message to let you knot that you need to release some locos if you want to select and run others. The DB150 manages the addresses that occupy slots by assigning different statuses to each decoder depending on how it is being used in the system. This allows the DB150 to ...
HELP!!!!!!!!If your Zephyr DCS50 display isn't showing you what you expect based on the manual, press the EXIT key to return to normal operating mode. Also make sure that the "Power" is on. Then try the throttle task again. If you think you might have made an inadvertent change to one of the factory settings in either the decoder or the command station, try resetting everything to the factory settings and try the task again. Please see the related articles (below).
If the DB150 unit shuts down occasionally due to a track short circuit: 1. Correct the short circuit condition and the booster will resume normal operation. 2. Turning off the booster when a short occurs is not necessary since it will re-start automatically when the short is cleared. If the DB150 unit shuts down frequently: 1. Move the DB150 so that the heat sink has a flow of cool air. 2. Place the DB150 out of direct radiant heat like sunshine or a room heater. 3. Try direct cooling by using a small fan to blow air onto the heat ...
My Atlas DCC N-Scale locomotives that are equipped with factory installed Lenz062xf, Lenz063xf decoders will not program using any mode on Program track. I know the system works because I can easily program every Digitrax decoder loco that I have, but if I put an Atlas DCC factory loco on the programming track I get the 'd nd' error code. There are decoders now present in the market that do not draw enough current for the programming track to reliably detect that they are present, hence the error report of "d-nd". All you have to do is to ...
A slot is a memory location in the command station that holds an active decoder address. The number of slots is the number of locomotives that the command station can support in operation at a time. When the available slots are filled with decoder addresses, trying to select another locomotive address to run generates the "slot=max" error code. When all the slots are full you can't select another address until one is released from the system. See Clearing your Command Station's Mobile Decoder Slots below for how to prevent this from happening.The DCS100 Command Station/Booster that is included with Super Chief Xtra and other ...
Stealing, or "sharing" is defined as acquiring control of a loco address that is being used by someone else on another throttle. To ‘Steal’ a loco:1. Unplug the UT4 from the LocoNet port.2. Dial up the address of the loco you want to steal.3. Press and hold the ‘STEAL’ key while plugging the throttle into the LocoNet jack. Note: To steal or dispatch another loco, you must unplug the UT4 and repeat the above sequence.
Installation: Figure 1 shows the general arrangement for connecting one or more LNRP's to configure a LocoNet based system for operation. Note that the LNRP's drive the power and Railsync signals on the "standard" LocoNet cable segments, so each LNRP should have a DC input of +15V to +18V at up to 250mA supplied on the side DC power jack. Note that the shaded cable connections are made from the protected network side connections of the LNRP units to the components that are on the "protected" or high reliability part of the System. The other solid cable connections are the ...
Digitrax DB150 Command Station/Booster Power On LED Diagnostic BlinkingSteady on = DB150 is operating as a Command Station/Booster 1/2 sec on / 1/2 sec off = DB150 is operating as a Booster only 1 sec on / 1 sec off = DB150 is in Option (OP) mode, the Option switch is in the OPTN position 2 sec on / 2 sec off = DB150 is in Sleep mode, the Option switch is in Sleep mode Fast pulsing = DB150 is in Program Mode, the Option Switch is in PROG mode. Commands sent in this mode will program decoders that are ...
The DCS100, 200, 240 and DB150 use several beeps and clicks that can be used as diagnostic tools that will help you debug a number of error conditions. DCS100/200 Audible Sounds 1 Beep DCS100/200 has powered on successfully or has sent a programming command. 3 Beeps A loco address has been "purged" due to non-use. This is informational only and is normal. 4 Beeps Booster short circuit shutdown. Fault Alarm. 6 Beeps Command station already present in system. When two command stations are operating on the same system, you may experience unexpected results. 7 Beeps DCS100/200 CMOS battery low ...
The DCS50 Zephyr displays three types of error messages: Short circuit shutdown occurs when the DCS50 detects a short circuit in the power district where it is connected to the layout. This can be a loco that has derailed or picked a switch or some other conductive material lying across the tracks. In this case you will see “o”s walking across the display from left to right. Once the short is cleared, the DCS50 will resume normal operations. Current overload occurs when the DCS50 has reached its 2.5 Amp current limit. In this case you should run fewer locomotives or ...
When you hear 7 beeps when power is applied to your DCS100, you need to replace the CMOS battery. The DCS100 will continue to operate, even if this battery is not present, but all your memory settings and option switch settings will not be remembered when the DCS100 is powered down. To replace the CMOS battery without losing any memory settings: 1. Remove the DCS100 input power & disconnect all DCS100 leads. 2. Open the DCS100 case: a. Remove the two screws on the top and bottom of each side of the case. b. Slide the gray front panel off ...
The green CONFIG Indicator shows the primary operating mode of the DCS100. This indicator should be steady green blinking off briefly once every 4 seconds. This indicates that the setting for DCS100 Option Switch 05 is set up correctly. If you see 8 blinks every 4 seconds then we recommend that you change the DCS100 Option Switch 05 to closed. The DCS100 will operate correctly in either case. The CONFIG Indicator will be mainly off when DCS100 option switch 01 is incorrectly set to closed. In this case you must change option switch 01 to thrown for correct operation.