Keep Alive Power Jack (For DT200 & BT2) When the layout is powered down we recommend that you change the DT200 that is running as the Command Station to Advanced Throttle mode so it can power down and conserve its battery. Do this by pressing Run/Stop & Left Arrow keys together. All other Advanced Throttles on LocoNet will power down and show "idLE" when the LocoNet bus wires (pins 3 and 4 of the RJ12 plug) fall below +5Volts for more than 1/4 of a second. If the RailSync lines on LocoNet (pins 1 and 6 of the RJ12 plug) ...
CV29 controls many aspects of the locomotive, including its decoder address (including two or four digit address) , normal direction of travel (NDOT), whether the locomotive opperates at 28 speed steps or 128 and others. Some older Digitrax throttles use hexadecimal notation for programming. This article is presented for the benefit of those who may still be using these throttles. CAUTION: if you are NOT using a DT100 or DT200, please disregard this article to avoid confusion.The Addition Method The table below shows each switch and its value if it is on or off. Notice that if the switch is ...
Is the DT 200 compatible with newer sets? The DT200 (now discontinued) was supplied with the Digitrax Big Boy starter set. The Big Boy system consisted of a DB100 configured as a booster, LA1 or LA2 LocoNet Adapter interface, DT200 throttle, and a power supply. The primary DT200 throttle also acted as the command station. The Big Boy system had full LocoNet capabilities. Unlike the Chief, this set depended on the DT200 as part of the of the system, with the throttle acting as the command station for the unit. With other LocoNet systems, such as Super Chief, it will ...
I own a Digitrax Starter Set that is now discontinued. Can I still use it and can it be upgraded?LocoNet lets you use all Digitrax LocoNet components in your system no matter when you purchased them. You can continue to use what you already own with new components as they become available. Note: This will work with all starter sets except for Challenger. If you have a Challenger Set and you want to move up, the best thing to do is to purchase one of the new sets and use the DB100 series booster that came with your Challenger as ...
The first Digitrax system to use LocoNet was Big Boy. Each Big Boy system came with a LocoNet Adapter 1 (LA1) or LocoNet Adapter 2 (LA2). Documentation for these units was minimal, but is included here. LA1 LA-1 came with a simple card: LA-1 LocoNet Adapter Use this cable to connect your DB100 to your DT200 command station unit and to your LocoNet command bus. The LA-1 allows you to connect more than one throttle to your Big Boy System. You only need one LA-1 in a Big Boy System. If you are upgrading to Big Boy from Challenger, you ...
What happens when I select a loco that is currently running at a different speed than the throttle is set to? example... running loco 'a' at half speed then switch to loco 'b' does loco 'b' suddenly change speed to half throttle? (which is the last position the knob was indicating for loco 'a' this would make for a nice crash if I planned on backing loco 'b' out of a siding, and it goes forward instead at 50% right into a bumper) You're right, when switching the loco 'b', the newly selected locomotive would be commanded to operate at ...
Digitrax defines the TOP loco as the loco on the R Throttle Knob at the time when the MU add is performed. This will be the locomotive address that controls the consist.