Digitrax Products -> Power Management Products -> PM42-Quad Power Manager/Auto Reverser -> PM42 - Power Manager Option Swiches
Q: What is the basic configuration and OpSw settings for a section of the PM42 when configured for circuit breaker control? A: The PM42 is a 4 section multi-purpose device where each of the four sections can be individually configured to act as either a circuit breaker, or automatic reverse loop controller. The PM42 monitors the current flow to the rails and interrupts the connection when it senses that the current demands exceed the upper allowable current level determined by the User controllable Option Switch (OpSw) settings. The power flow of a layout's command control system starts with the command station, or ...
Q: What is the basic configuration and Option Switch (OpSw) settings for each of the four sections of the PM42 when configured for automatic reverse section control? A: The PM42 is a 4 section multi-purpose device where each of the four sections can be individually configured to act as either a circuit breaker, or auto-reverse section controller or DPDT relay. When configured as an auto-reverse section controller, the PM42 adjusts the rail phasing of the reversing section it controls whenever a locomotive, or car with metal wheels, bridges the gaps between the rails of that reverse section and an adjacent non-reversing section ...
PM42 Short Circuit/Auto-Reversing Failure When used with Zephyr (DCS50) The PM42 is designed to control 4 independent power subdistricts that can be set up as either a “Short Circuit Manager” (the factory setting) or as an “Auto-Reversing Controller.” The PM42 factory setting for trip current is 3 amps. The trip current can be modified to settings from 1.5 amps – 12 amps to accommodate the needs of your system. In addition, each of the 4 power subdistricts can be set for slow, regular, faster or fastest short circuit management. While a trip current of 3 amps will work with most ...
Q: How do I program the PM42 Option Switches (OpSw) with a DT400 throttle? A: The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSws is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the DT400 series throttle with any Digitrax command system. 1) Connect the PM42 to a DCS50, DCS51, DB150, DCS100, or DCS200 with a standard LocoNet cable. 2) Connect the PM42 to an external power source; Digitrax ...
Q: How do I program the PM42 Op Switches with a DT300 throttle? A: The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSws is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the DT300 throttle with any Digitrax command system. 1) Connect the PM42 to a DB150, DSC050, DSC100 or DSC200 with a standard LocoNet cable. 2) Connect the PM42 to an external power source; Digitrax recommends the ...
How do I program the PM42 Op Switches with a DCS50 (Zephyr) throttle? The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSw's is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the keypad of a Digitrax Zephyr. 1. Connect the PM42 to the Digitrax Zephyr with a standard LocoNet cable. 2. Connect the PM42 to an external power source; Digitrax recommends the PS14. Note: Before entering Switch Mode ...
Q: What is the preferred way of protecting a reverse loop with circuit breaker management and still having automatic reversing? A: There are two ways of protecting a reversing section with a circuit breaker and reversing section controller. 1. Use one PM42 (circuit breaker manager) and one AR1 (automatic reversing section controller). 2. Use two PM42s (one as a circuit breaker manager and one as a reverse section control). The following diagram displays both methods: a) The first method (left), is where one section of a PM42 configured for circuit breaker operation feeds one or more AR1s (automatic reversing section controller), or b) The second method ...
Q: Can two sections of a single PM42 be configured to perform both the task of a circuit breaker and also automatic reverse section control for a single reverse loop? The PM42 can be configured so that one section of the PM42 is used for circuit breaker operation, feeding into another section of the same PM42 which is configured for automatic reverse section control. In the field, this configuration has been found to be unreliable in some layout configurations. If you are having problems getting this to work in your setting, we recommend using an AR1 to handle the automatic reversing secion. The ...