Option switches are used to change the operation of the DB150.
Option Switch # |
Effect on system when Option Switch “c” closed |
Default |
OpSw 02 |
Booster Only override |
t |
OpSw 03 |
DB150’s booster is auto reversing |
t |
OpSw 05 |
Default closed for command station –DO NOT CHANGE- |
c |
OpSw 13 |
Loco purge time extended from 200 seconds to 600 seconds |
t |
OpSw 14 |
Loco purging is disabled |
t |
OpSw 15 |
Purging will force loco to Stop or 0 speed |
t |
OpSw 17 |
Automatic advanced decoder assisted [FX] consists are disabled |
c |
OpSw 18 |
Extend the DB150 booster short circuit shutdown time from 1/8th to ½ second |
t |
OpSw 20 |
Disable address 00 or analog stretching for conventional locomotives. Always “c” for German DB150’s |
t |
OpSw 21 |
OpSw 21-23 set the global system default type for “NEW” loco selections. Set Sw 21/22/23 As follows: t-t-t 128 step mode (factory default) t-t-c 14 step mode t-c-t 28 step mode c-t-t 128 step FX c-c-t 28 step FX |
t |
OpSw 22 |
t |
|
OpSw 23 |
t |
|
OpSw 25 |
-DO NOT CHANGE- |
c |
OpSw 27 |
Disable normal switch commands, a.k.a. the “Bushby bit” Allows attached PC to perform switch control logic |
t |
OpSw 33 |
Allow track power to restore to prior state at power on |
c |
OpSw 34 |
Allow track to power up to run state, if was run prior to power down |
c |
OpSw 36 |
Reset/ clear/ erase all mobile decoder information & consists |
t |
OpSw 38 |
Erase/clear the loco roster |
t |
OpSw 39 |
Clear all internal memory states, including sections. OpSw 36/37/38 clears |
t |
OpSw 41 |
Diagnostic click when valid LocoNet commands incoming (useful for debug) |
t |
OpSw 42 |
Disable 3 beeps on purging a loco |
t |
OpSw 43 |
Disable LocoNet update of command station’s track status |
t |
OpSw 49 |
No beep when DB150 sends program command |
t |
OpSw 50 |
Longer booster short circuit recovery time |
t |
OpSw 51 |
Do not allow EXT voltage RESTART (with 2nd booster wired in parallel) |
t |