EMD 567B-16 FP7A Non Turbo (Roots) 1500HP
The EMD FP7 was a 1,500 horsepower (1,100 kW), B-B dual-service passenger and freight-hauling diesel locomotive produced between June 1949 and December 1953 by General Motors' Electro-Motive Division and General Motors Diesel. Final assembly was at GM-EMD's La Grange, Illinois plant, excepting locomotives destined for Canada, in which case final assembly was at GMD's plant in London, Ontario. The FP7 was essentially EMD's F7A locomotive extended by four feet to give greater water capacity for the steam generator for heating passenger trains.
Sound Projects
Custom sound scheme. Sept 25, 2013 NOT for resale. (C) Copyright John McMasters 2013, used with permission.
EMD 567B-16 FP7A 12/12/2013
DN0_4chnl_x6_FP7.SPJ Version 1.5
SDF: DN0_4chnl_x6_FP7A
BASE CODE: DN0_4chnl_x6 -- Discrete Notching, 4 Channel, SDF Ver 2
SOUND SET: EMD 567B-16 FP7A 6133 44KHz
CHANNELS: 4
SERIES: 6
Author: John McMasters Custom sound scheme. Sept 25, 2013 NOT for resale.
(C) Copyright John McMasters 2013, used with permission.
EMD 567B-16 FP7A 6133
----------------------------------------------------------------------------
INTRODUCTION
----------------------------------------------------------------------------
This is the Sound Definition Langauge (SDL) file for a project that can be
used for a typical diesel locomotive. Supported
sound effects include bell, dynamic brakes, air brake system,
and coupler crash.
Power type Diesel-electric
Builder General Motors Electro-Motive Division(EMD)
General Motors Diesel (GMD, Canada)
Model FP7A
Build date February 1949 – December 1953
Total production 2,366 A units, 1,483 B units
AAR wheel arr. B-B
Gauge 4 ft 8 1/2 in (1,435 mm)
Wheel diameter 40 in (1.016 m)
Length A unit: 50 ft 8 in (15.44 m)
B unit: 50 ft 0 in (15.24 m)
Width 10 ft 7 in (3.23 m)
Prime mover EMD 16-567B
Cylinders V16
Power output 1,500 hp (1,100 kW)
----------------------------------------------------------------------------
DESIGN NOTES
----------------------------------------------------------------------------
NOTE:
CV155 Notching mode should(must) be =1: 0 = Auto, 1 = Semi auto, 2 = Manual [1]
Features:
Discrete notching with transitions
Auto coupler/coupler slack sounds
Auto braking with variations; Moving manual brakes; Hand brake or Dynamics
Auto distance event (grade crossing) option
Directional Toots option
Multiple air sounds
Bell and Horn Selector
Sander
Wheel/track sounds
Boxcar boom and other user defined sounds
Selectable notch 1-8 control
Estop is a motor control; startup motor interlock
Operator can select AUX with F19 to turn on the auxiliary diesel generator for passenger consists.
Configuration CV for option disables
Series 6 extended features are exploited (additional CV range above 155, Xplay long sounds)
Changes:
1) interlock scatter events for when motor disabled 6/10/2013
2) fix bug notch acceleration comparison to us NOTCH_MASK to only compare bits0-7
3) fixed waver on volt change 6/30/2013
4) fix coupler slack when not moving 6/30/2013
5) adjust running volume 7/1/2013
6) Replaced ;; #INCLUDE "C:\SPJ_Projects\sdn136\SERIES6_SND_MACS.INC" WITH
#INCLUDE "C:\SPJ_Projects\sdn136\SERIES6_snd16_macs.inc" for handles greater than 64 7/26/2013
7) disable motor run during start sounds -- WKSB_RUN_MASK,MERGE_ALL_MASK
;set the RUN bit to enable 7/24/2013
8) Maximise running volume: MASTER VOLUME CV58 SHOULD BE LESS THAN 60% OF
MAX (about=8) . CV140 PRIME_VOLUME SHOULD LESS THAN about 60 7/27/2013
9) Normalize sounds 8/5/2013
10) Fix HEP interlock missing tests 8/6/2013
11) Revise CV extended list 8/7/2013
12) Remove RUNUP_INTERLOCK 8/9/2013
13) Activate bit2 disable startup 9/18/2013
14) Reverted to cv132 notch rate of =127 default 10/7/2013
15) Replace _DIESEL_9/15/2013
16) Remove decelerate to stop routine 9/16/2013
17) F3 OFF directional toots 9/22/2013
18) F15-SANDER F16-MISC USER CHATTER 9/23/2013
19) Final Copyright 9/23/2013
20) Modify runup, inc_12 10/5/2013
21) Re-write NOTCH_VALUE0_9, all discreet notching routines 10/7/2013
22) Revise NOTCH_VALUE0_9 transitions AND RUN IN 2-8 IDLE only run1 10/10/2013
23) Removed Decrease to idle and revise IDLE/not moving Phase
24) Move EStop to F8 on with F9 on 10/22/2013 (EStop will disable motor movement) F8 alone will just mute sounds.
25) Skip startup sounds when F8 is already on 10/22/2013
26) Play hand brake on F5 when stopped (remove F11 for other functions)
27) Move F13 to F11
28) Revise EStop on with F14
29) Revise Horn and bell timing 10/30/2013
30) On transition from idle notch up when delte = 0 11/4/2013 []ncrease to run]
31) Brake lock out motor on F9 stopped 11/7/2013
32) Revise volume levels by -20 11/7/2013
33) Add bell select CV157 [SCV_157_SEL_BELL] 11/7/2013 BELL, GRADE CROSSING
34) Remove HEP and add AUX routines 11/15/2013
35) Initial idle trim CV167 11/23/2013
36) GEN1 Transition sounds
37) Modify WORK_SPEED,IMMED_DATA,0x01,COMP_ALL,SKIP_GRTR ; Check if stopped 12/5/2013
38) Move F4 to F13 12/6/2013
Objectives:
1) Use 4 channels (voices) avoiding previous version
interruptions.
2) Assign large 44KHz 16bit sound samples for best
audio results
3) optional startup sounds disable when F0 is on
4) Feature disable CV169 is HEX values to disable features like HEP mode:
bit0 disable HEP diesel ARTICULATED steam
bit1 disable hard automatic braking
bit2 disable startup sounds
bit3 disable Fans
bit4 disable toots on direction change
bit5 disable grade crossing random play
bit6 disable bell
bit7 fuel prime once for Gen1 diesels OR
multiple start warning bells Gen2
6) F21-F28 Select Notch 1-8
----------------------------------
FUNCTION KEYS DEFINED:
----------------------------------
(A) Function Key Usage:
F0- Lights [disables startup sounds when on during initialization]
F1- Bell
F2- Horn CV150 selects Horn type ( 0=normal 2=playable default 0)
F3- Auto Coupler coupler clank and BRAKE if F3 is ON, is dir chng and last PK spd below e.g. CV151
[Autocoupler/brake set by CV151 max spd] F15 on for un-coupler
[Leave F3 on for auto coupler]
Toggle OFF plays directional toots
F4- Reserved for light function (turn on rear light, etc.)
F5- Dynamic brake fans [Handbrake while stopped. Handbrake loop will PLAY until F5 Off]
F6- Notch UP If CV155 is not 00 F6 is ON trig BLOWOFF/drier then compressor ONE time /NOTCH UP...
IF any manual notching: F6 is NOTCH UP and F7 is NOTCH DOWN!!
F7- Notch down [If CV155 is not 00 F7 is CROSSING HORN WHEN
AUTOMATIC notching selected in SCV155=0]
F7 ON Is now notch down for EVENT, integrate -VE in SPEED_DELTA
F8- Mute control [F8 to ON is muted to cv volume, F8 off, set REG volume]
F9- Brake squeal [Leave F9 on for auto brakes]
F10- Grade crossing horn sequence [Bell stays on until F10 off]
F11- UNCoupling (disables toots on F3)
F12- Wheel Squeal (continuous when moving) [Disables bell on F6]
F13- Air features disable F13 is ON =disable AIR sound/FEATURES, trig BLOWOFF/drier then compressor ONE time
[F13 off enables pop-off, drier and compressor]
F14- EStop Shutdown (disables motor movement until OFF)
F15- SANDER
F16- MISC USER CHATTER
F17- BoxCar Boom
F18- MISC USER SND
F19- Enables AUX generator
F20- MISC USER SND
F21-F28 Select Notch 1-8 7/17/2013
(B) Diesel Sound FX defined CV's: [decoder CV8=8 reset value in brackets]
CV58 Master Volume, 0-15, 0= max, (F8 used for Mute) [7]
CV60 Scheme select CV, 0=Steam/Diesel [0]
CV122 Product TYpe, 12 = Digitrax SFX sound decoder Read Only Value
CV123 Hardware Version Read Only Value
CV132 Diesel Notch rate 64-127 [64]
CV133 Steam Chuff/CAM config, 128=>EXT cam, 1-127=>DRIVER dia in inches[63]
CV134 Steam gear ratio trim, 32=100% ratio, [32]
CV135 Volume when Muted 0-64 [0]
CV139 Set to trigger distance event 0-64 [30]
CV140 Prime Mover Volume 0-64 [58]
CV141 Bell Volume 0-64 [52]
CV142 Horn Volume 0-64 [61]
CV143 AIR feature volume, drier, compressor, brake release Air sounds Volume 0-64 [59]
CV144 Dynamic brake volume 0-64 DIESEL DYNAMIC brake volume [60]
CV145 Miscellaneous volume 0-64 [58]
CV146 Delay between Bells 1-100 [04]
CV147 Time between Drier cycles Users normally reset drier rate to 10 or more [22]
CV148 Time between Compressor cycles [30]
CV149 Compressor run time [24]
CV150 HORN selector 0=normal 2=playable [0]
CV151 Speed limit FOR AUTOMATIC COUPLER/BRAKE on DIR chng. about 1/2MPH per unit [38]
CV152 defines USER code for this SDF
CV153 SUB id SCHEME/SDF
CV154 STEAM blowdown volume [45]
CV155 fact default is AUTO NOTCHING; CV54 needs to be zero for F7 Notch UP [1]
CV156 is 540mS HORN delay for SHORT [1] slows horn attack
CV157 is FOR bell selection [00]
CV158 is
CV159 is
CV160 is VARIANT id
CV161 Power Reverser volume 0-64 [50]
CV162 Grate Shaker Volume 0-64 [50]
CV163 Water fill/Coal fill Volume 0-64 [54]
CV164 Compressor Volume 0-64 [48]
CV165 Steam Boiler Volume/Diesel Fan Volume 0-64 [35]
CV166 Coupler Slack Volume 0-64 [32]
CV167 Initial Idle Trim 0,16,32 [16] {IS hex 0x00 notch1, 0x10 notch2, 0x20 notch3}
CV168 AUX GEN/Stoker Volume 0-64 [51]
CV169 is HEX values to disable features like HEP mode:
; bit0 disable ARTICULATED steam HEP diesel
; bit1 disable hard automatic braking
; bit2 disable startup sounds
; bit3 disable Fans
; bit4 disable toots on direction change
; bit5 disable grade crossing random play
; bit6 disable bell
; bit7 fuel prime once for Gen1 diesels OR multiple start warning bells Gen2
CV170 Safety Run Time 0-64 [22]
CV171 ALT HORN volume 0-64 [60]
CV172 Water Pump Cycle Time 0-64 [31]
CV173 Cutoff Speed for Auto Cyl. blow down 0-64 [22]
CV174 Air Compressor run time 0-255 [31]
CV175 Stoker/oil pump run time 0-255 [18]
CV176 F28_user run time scattered sounds 0-255 [20]
=================================
(C) General Notes
This is a functional tested version of a project using individual sound recordings for each prime mover notch setting. These
prime mover sounds can be played in three modes determined by CV155: automatic, semi-automatic and manual notching. In auto
mode, the prime mover notch is determined by the current speed setting, and is adjustable using CV132. In semi-auto mode,
the same is true but it is possible to "throttle up" to higher notches using F6 and F7, if you want your engine to sound
like it is working harder. Manual mode offers full control of the notch setting using F6 and F7, so you can throttle down
to idle and turn on dynamic braking while coasting downgrade.
Other features available in this project include:
- Automatic grade crossing horn sequence with bell
- Optional highball and backup horn signals while stopped
- Dynamic brakes at speed or standing
- handbrake while stopped
- Automatic coupler sounds when changing direction at low speeds
- Automatic brake squeal sounds when decelerating to a stop
- Manual brake squeal on F9 and moving
- Additional user-defined sounds on F14 and F15
This sound project has been assembled from Digitrax-supplied sound clips as well as new sounds from custom recordings.
Additional custom 16bit 44KHz files were used to edit individual sound fragments (WAV files for each file handle).
It will be a copyrighted project on acceptance by Digitrax.
Thanks are due to A.J. Ireland for their prior work in developing sound projects.
** Switching speed is enabled by setting CV 54 to 1 with back EMF or 3 without back EMF
For CV155=01 ["Semi_automatic Notching"], the Prime mover lowest Notch setting is set by
the throttle speed setting. F6 (ON) can increase the Notch and F7 (ON) will decrease the
Prime mover to the minimum notch set by current throttle setting.
The sound volume is controlled by Master Volume CV58 as well as any individual sound
volume CVs. The Default for CV58 is 5 but can be set 0-15 from a Throttle or the sim-
ulated throttle in SoundLoader. Individual sound volume CVs can be set 0-64.
Problems and exceptions:
NOTCH RATE (CV132)
Default is CV132=127 but that bunches the notches at the lower portion
of the throttle range. 64-127 or higher is OK when your motor takes very little current.
A value of 71 will spread the notches across the whole range, but may leave your
engine moving too fast. It should run at scale speeds and notch.
------[end SDF/DECODER definition]--------------
SoundLoader Software
Using your PR3 programmer and SoundLoader Software, it’s quick and easy to download sound project files into your Digitrax FX decoders.
Format Information
With Digitrax Sound FX decoders and downloadable sound project files (.spj), you can download your choice of sound schemes into any Sound FX equipped locomotive. You can use spj’s that are available for free, you can modify those schemes or you can create your own!
Sound Decoders
Digitrax offers a wide variety of Sound FX decoders to fit many different locomotives. You’ll need to have a Digitrax SFX decoder installed to take advantage of using .spj files.
Click here for Digitrax Sound FX decodersSubmit your Sound Projects
Use our submission form to submit your Sound Projects
Click here to submit your sound project