DCS240 LocoNet® Advanced Command Station
This product has been replaced by the LocoNet® Advanced Command Station (DCS240+) and is no longer available. Click here to view the DCS240+.More Locos
More Capacity
Really Big Fun!
The DCS240 Advanced Command Station lets your LocoNet® System run up to 400 locos and 400 throttles. Full read/write programming, route capability, USB connectivity, and separate programming output lets you run and program at the same time.
-
5 or 8 Amps of Power
-
400 Loco Addresses
-
400 Throttle Support
-
Combination Advanced LocoNet® Command Station and 8 amp CTC booster
-
User selectable N,HO, and large scale operation with Voltage Trim
-
LocoNet for easy plug ‘n play installation and system expansion
-
Auto resetting over temperature and short circuit protection
-
Hardware EZ routes and Loco Reset
-
Integrated USB for Computer Support
-
Over-Voltage Protected
-
Auto shutdown when command control signal is lost to prevent “runaway” trains
Note: Accepts DC POWER input ONLY from power supply (sold separately). Recommended power supply: Digitrax PS514 or equivalent. MAXIMUM INPUT 8 AMPS, 24VDC, 192 VA MAXIMUM CONTINUOUS, DO NOT Exceed 25VDC maximum Input. Minimum Input 13VDC.
Technical Note About DCC Booster Output Ratings: Digitrax boosters have maximum output current limits of either 5 or 8 amps. The actual continuous output current that your booster will provide to the layout depends on several factors including the input supply voltage, the ambient room temperature and air flow over the booster's heat sink. Higher input voltages increase the amount of heat that must be dissipated by the booster's heat sink. If the heat sink does not get enough air flow to allow for heat dissipation, the booster will eventually reach an over temperature state and shut down. A small fan blowing across the heat sink on your booster will increase the maximum sustained current output capacity of your booster.
Each DCC company specifies the output capacity of its boosters according to their own internal standards. Tests designed and performed by several model railroaders have shown wide variations in the actual output capacity of DCC boosters. In most cases the tests were designed to overload boosters and cause them to shut down. The conclusion based on these tests is that each manufacturer uses a different way of determining booster output capacity, Digitrax tends to be more conservative in stating booster output ratings. The factor that is most important for achieving maximum output capacity is the booster’s heat sinking ability. In these tests, Digitrax boosters have demonstrated excellent heat sinking capabilities and the ability to consistently output the advertised 5 or 8 amps when appropriate fans are added in high temperature situations.
Specifications
- Size
- 5.39" X 4.05" X 3.26" (137mm X 103mm X 83mm)
- Original Release Date
- 06/24/2016
- Warranty
- No Worries Warranty (read more)
Digitrax gives a one year "No Worries" Warranty against manufacturing defects and accidental customer damage
on all Digitrax command stations, boosters, throttles, decoders, power supplies and layout control devices.
That's it! A simple, straightforward warranty with no tricky language!
Repairs are simple, too! Just fill out the form and return your items directly to Digitrax for repair. We'll get them fixed up and return them to you as quickly as possible. Please DO NOT return items for repair to the place of purchase.
Make Sure Your Item Needs To Be Repaired Before Sending It To Us! Many of the units we receive for repair do not need any repairs at all. Before you send any units for repair, please take a few minutes to review our Support Options.
1. Check the Tech Support Depot for help. Search for troubleshooting guides.
2. Click here to send Digitrax Tech Support a message.
Please give your name, e-mail address, phone number and when is the best time to contact you. Please give a complete description of the issue you are having.
Many problems are easily resolved by contacting Digitrax Tech Support without having to send in your unit.
Note: Some Digitrax products are no longer repairable due to unavailability of repair parts. Un-repairable items will be returned to you at no charge with no repairs made.
Please Note: Most of our products are not user serviceable. If a defect or accidental damage occurs, return the unit directly to Digitrax for service. Please do not open the Command Station/Boosters (except for making voltage adjustments or changing batteries per the manuals). Please do not remove the shrink wrap protective sleeves from the Digitrax decoders. Shrink may be peeled back to expose pads for adding function wires.
Accessory items that are not covered under the No Worries Warranty carry a 90 day warranty against defects in materials and workmanship. This includes speakers, wire, cables, battery covers, etc.
Intentional damage and customer modifications outside the scope of instructions provided with the product are not covered by this warranty.
Do NOT send a locomotive with your decoder. If a locomotive is sent to Digitrax, Digitrax will ship the entire package back, unrepaired.
- Booster Current Rating
- 5 Amps or 8 Amps depending on power supply used