| CV# |
Feature |
Default |
Range |
Notes |
| 2 Digit and 4 Digit Addressing |
|
|
|
|
| 01 |
2 Digit Decoder Address |
003/X03 |
001-127 |
|
| 17 |
4 Digit Address Hi Byte |
000/X00 |
0128-9983 |
CV17 & 18 are used |
| 18 |
4 Digit Address Lo Byte |
000/X00 |
0128-9983 |
together |
| 29 |
Configuration Register |
006/x06 |
Table 29 |
|
| Configuration Register |
|
|
|
|
| 29 |
Configuration Register |
006/x06 |
Table 29 |
|
| |
Speed Step Control |
28/128 |
14 or 28/128 |
|
| |
Speed Table On/Off |
Off |
Speed Table On or Off |
|
| |
Analog Mode Conversion On/Off |
On |
On or Off |
|
| |
Normal Direction of Travel (NDOT) |
|
|
Not Available |
| |
Address Selection, 2 or 4 digit |
2 Digit |
2 or 4 Digit |
|
| LocoMotionTM |
|
|
|
|
| Acceleration & Deceleration |
|
|
|
|
| 03 |
Acceleration Rate |
000/x00 |
000/x00 to 031/x1F |
128 Steps |
| 04 |
Deceleration Rate |
000/x00 |
000/x00 to 031/x1F |
128 Steps |
| Three Step Speed Table-Start, Mid, Max Voltage |
|
| 02 |
Start Voltage |
000/x00 |
000/x00 to 255/xFF |
128 Steps |
| 05 |
Maximum Voltage |
000/x00 |
000/x00 to 255/xFF |
28 Steps000/x00, 001/x01 & 255/xFF= max voltage at step 28 |
| 06 |
Mid Point Voltage |
000/x00 |
000/x00 to 255/xFF |
28 Steps000/x00 & 001/x01= straight line curve |
| 28 Step Speed Tables |
|
|
|
|
| 65 |
Kick Start value |
000/x00 |
|
28 Step |
| 66 |
Forward Trim |
000/x00 |
|
28 Step |
| 67 |
First Speed Table Entry |
000/x00 |
|
28 Step |
| 68-93 |
28 Step Speed Table Entries |
000/x00 |
|
28 Step |
| 94 |
Maximum Speed Table Step |
000/x00 |
|
28 Step |
| 95 |
Reverse Trim |
000/x00 |
|
28 Step |
| 29 |
Configuration Register |
006/x06 |
Table 29 |
Set to enable speed tables |
| Torque Compensation & Switching Speed |
|
|
|
|
| 53 |
Not Available |
|
|
Not Available |
| 54 |
Torque CompensationSwitching Speed |
|
|
Not Available |
| Functions |
|
|
|
|
| 13 |
DC Functions ON |
000/x00 |
|
Not Available |
| Configurable Strobes |
|
|
|
|
| 49 |
F0F,forward light effect |
|
|
Not Available |
| 50 |
F0R, reverse light effect |
|
|
Not Available |
| 61 |
Enable Configurable Strobe |
|
|
Not Available |
| Standard, FX & FX3 Functions |
|
|
|
|
| 49 |
F0F, forward light effect white |
|
|
Not Available |
| 50 |
F0R, reverse light effect yellow |
|
|
Not Available |
| 51 |
F1, Function 1 green |
|
|
Not Available |
| 52 |
F2, Function 2 violet |
|
|
Not Available |
| 53 |
F3, Function 3 brown |
|
|
Not Available |
| 54 |
F4, function 4 white/yellow |
|
|
Not Available |
| 115 |
F5, Function F5 white/green |
|
|
Not Available |
| 116 |
F6, Function F6 white/blue |
|
|
Not Available |
| 62 |
FX Rate and Keep alive adjust |
|
|
Not Available |
| 63 |
Ditch Light Blink hold time |
|
|
Not Available |
| Directional Headlights, Transponding, Split Field Motor |
|
|
|
|
| 61 |
Directional Headlight |
Directional |
Table 61 |
|
| |
Transponding |
|
|
Not Available |
| |
Split Field Motor |
|
|
Not Available |
| Scaleable Speed Stabilization |
|
|
|
|
| 55 |
Static Compensation |
|
|
Not Available |
| 56 |
Dynamic Compensation |
|
|
Not Available |
| 57 |
Speed Stabilizer-Droop |
|
|
Not Available |
| SuperSonic |
|
|
|
|
| 09 |
Motor Frequency SuperSonic |
|
|
Not Available |
| Advanced Consisting |
|
|
|
|
| 19 |
Advanced Consist Address |
|
|
Not Available |
| 21 |
Advanced Consist Function Control Override for F1-F8 |
|
|
Not Available |
| 22 |
Advanced Consist Function Control Override for F0 & F9-F12 |
|
|
Not Available |
| Function Remapping |
|
|
|
|
| 33-46 |
Function Remapping CVs |
|
|
Not Available |
| Decoder Factory Reset |
|
|
|
|
| 08 |
Reset Decoder to Factory Default CV Values |
|
|
Not available |
| IDs |
|
|
|
|
| 105 |
User Private ID #1 |
000/x00 |
000/x00 to 255/xFF |
|
| 106 |
User Private ID #2 |
000/x00 |
000/x00 to 255/xFF |
|
| 07 |
Version ID |
000/x00 |
000/x00 to 255/xFF |
Read/Write |
| 08 |
Manufacturer ID |
129/X81 |
129/x81 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|